• search hit 22 of 24
Back to Result List

Self-Monitoring of Blood Glucose Levels Requires Intensive Training for Use of Meters to Obtain Reliable and Clinically Relevant Measurements

  • Background:Anecdotal reports from pediatric sites have indicated that some blood glucose meters may display wrong and misleading numbers rather than error indications, when operated in deviation from the instructions for use (IFU), eg by manipulating the strip during the count-down phase.Methods:This study was performed with 60 patients with diabetes (32 female, 28 male, 21 type 1, 39 type 2, age (mean±SD): 56±11 years) who measured their blood glucose levels twice with five different blood glucose meters (Precision? Xceed? [Abbott Medisense], Freestyle Mini? [Abbott Medisense], Accu-Chek? Comfort [Roche Diagnostics], Accu-Chek? Aviva [Roche Diagnostics], and Ascensia Contour? [Bayer Vital]). The first measurement was performed in accordance with the IFU, and the second by manipulating the test strip using a standardised inflexion/release procedure during the count-down phase. A standard glucose oxidase method (SuperGL) served as laboratory reference.Results:All meters worked in full compliance with current accuracy standards when operated according to the IFU. When manipulating the test strip, the results varied considerably: While changes in reliability were acceptable for two devices (Precision? Xceed?, Freestyle Mini?), the other devices produced an unacceptable number of errors and a series of entirely wrong values without error indication.Conclusions:The use of all devices is recommended when used according to the IFU. The use under the artificially induced impaired testing conditions is a major concern. This study underlines the importance of appropriate patient training regarding adherence to the IFU of glucose meters.

Export metadata

Additional Services

Share in Twitter Search Google Scholar Availability
Metadaten
Document Type:Article
Language:English
Author:Thomas A. Mohr, Andreas Pfützner, Senait Forst, Thomas Forst, Thomas Schöndorf
Parent Title (English):J Diabetes Sci Technol. (Journal of Diabetes Science and Technology)
Volume:1
Issue:1
First Page:56
Last Page:61
ISSN:1932-2968
DOI:https://doi.org/10.1177/193229680700100110
Publisher:SAGE Publications
Place of publication:London
Date of first publication:2007/01/01
Departments, institutes and facilities:Fachbereich Angewandte Naturwissenschaften
Dewey Decimal Classification (DDC):6 Technik, Medizin, angewandte Wissenschaften / 61 Medizin und Gesundheit / 610 Medizin und Gesundheit
Entry in this database:2018/07/04