Refine
H-BRS Bibliography
- yes (39) (remove)
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (39) (remove)
Document Type
- Article (39) (remove)
Year of publication
Language
- English (39) (remove)
Keywords
- Chemometrics (3)
- DNA typing (3)
- Raman spectroscopy (3)
- Classification (2)
- Discriminant analysis (2)
- Principal Components Analysis (2)
- Raman-microspectroscopy (2)
- SERS (2)
- Short tandem repeat (STR) (2)
- automated sensor-screening (2)
In this work, the surface reactions of the homemade explosive triacetone triperoxide on tungsten oxide (WO3) sensor surfaces are studied to obtain detailed information about the chemical reactions taking place. Semiconductor gas sensors based on WO3 nanopowders are therefore produced and characterized by scanning electron microscopy, X-ray diffraction, and Raman spectroscopy. To analyze the reaction mechanisms at the sensor surface, the sensor is monitored online under operation conditions using Raman spectroscopy, which allows to identify the temperature-dependent sensor reactions. By combining information from the Raman spectra with data on the changing resistivity of the underlying semiconductor, it is possible to establish a correlation between the adsorbed gas species and the physical properties of the WO3 layer. In the results, it is indicated that a Lewis acid–base reaction is the most likely mechanism for the increase in resistance observed at temperatures below 150 °C. In the results, at higher temperatures, the assumption of a radical mechanism that causes a decrease in resistance is supported.
A deployment of the Vehicle-2-Vehicle communication technology according to ETSI is in preparation in Europe. Currently, a policy for a necessary Public Key Infrastructure to enrol cryptographic keys and certificates for vehicles and infrastructure component is in discussion to enable an interoperable Vehicle-2-Vehicle communication. Vehicle-2-Vehicle communication means that vehicles periodically send Cooperative Awareness Messages. These messages contain the current geographic position, driving direction, speed, acceleration, and the current time of a vehicle. To protect privacy (location privacy, “speed privacy”) of vehicles and drivers ETSI provides a specific pseudonym concept. We show that the Vehicle-2-Vehicle communication can be misused by an attacker to plot a trace of sequent Cooperative Awareness Messages and to link this trace to a specific vehicle. Such a trace is non-disputable due to the cryptographic signing of the messages. So, the periodically sending of Cooperative Awareness Messages causes privacy problems even if the pseudonym concept is applied.
Intimate swabs taken for examination in sexual assault cases typically yield mixtures of sperm and epithelial cell types. While powerful, differential extraction protocols to overcome such cell type mixtures by separate lysis of epithelial cells and spermatozoa can still prove ineffective, in particular if only few sperm cells are present or if swabs contain sperm from more than one individual leading to complex low level DNA mixtures. A means to avoid such mixtures consists in the analysis of single micromanipulated sperm cells. However, the quantity of DNA from single sperm cells is not sufficient for conventional STR analysis. Here, we describe a simple method for micromanipulating individual sperm cells from intimate swabs and show that whole genome amplification can generate sufficient amounts of DNA from single cells for subsequent DNA profiling. We recovered over 80% of alleles of haploid autosomal STR profiles from the majority of individual sperm cells. Furthermore, we demonstrate that in mixtures of sperm from two contributors, Y-STR and X-STR profiles of individual sperm cells can be used to sort the haploid autosomal profiles to develop the diploid consensus STR profiles of the individual donors. Finally, by analysing single sperm cells from mock sexual assault swabs with one or two sperm donors, we showed that our protocols enabled the identification of the unknown male contributors.
Design of an Active Multispectral SWIR Camera System for Skin Detection and Face Verification
(2016)
Biometric face recognition is becoming more frequently used in different application scenarios. However, spoofing attacks with facial disguises are still a serious problem for state of the art face recognition algorithms. This work proposes an approach to face verification based on spectral signatures of material surfaces in the short wave infrared (SWIR) range. They allow distinguishing authentic human skin reliably from other materials, independent of the skin type. We present the design of an active SWIR imaging system that acquires four-band multispectral image stacks in real-time. The system uses pulsed small band illumination, which allows for fast image acquisition and high spectral resolution and renders it widely independent of ambient light. After extracting the spectral signatures from the acquired images, detected faces can be verified or rejected by classifying the material as "skin" or "no-skin". The approach is extensively evaluated with respect to both acquisition and classification performance. In addition, we present a database containing RGB and multispectral SWIR face images, as well as spectrometer measurements of a variety of subjects, which is used to evaluate our approach and will be made available to the research community by the time this work is published.
This paper presents recent research on an active multispectral scanning sensor capable of classifying an object's surface material in order to distinguish between different kinds of materials and human skin. The sensor itself has already been presented in previous work and can be used in conjunction with safeguarding equipment at manually-fed machines or robot workplaces, for example. This work shows how an extended sensor system with advanced material classifiers can be used to provide additional value by distinguishing different materials of work pieces in order to suggest different tools or parameters for the machine (e.g. the use of a different saw blade or rotation speed at table saws). Additionally, a first implementation and evaluation of an active multispectral camera system addressing new safety applications is described. Both approaches intend to increase the productivity and the user's acceptance of the sensor technology.
A series of reactive binaphthyl‐diimine‐based dopants is prepared and investigated with respect to their potential for the chiral induction of structural coloration in nematic liquid crystal mixture E7 and the selective photonic sensing of nitrogen dioxide (NO2). Studies of the helical twisting power (HTP) in 4‐cyano‐4′‐pentylbiphenyl (5CB) reveal HTP values as high as 375 µm‐1 and the tremendous impact of structural compatibility and changes of the dihedral binaphthyl angle on the efficiency of the chiral transfer. Detailed investigation of the sensing capabilities of the systems reveals an extraordinarily high selectivity for NO2 and a response to concentrations as low as 100 ppm. The systems show a direct response to the analyte gas leading to a concentration‐dependent shift of the reflectance wavelength of up to several hundred nanometers. Incorporation of copper ions remarkably improves the sensor's properties in terms of sensitivity and selectivity, enabling the tailored tweaking of the system's properties.
With the increasing demand for ultrapure water in the pharmaceutical and semiconductor industry, the need for precise measuring instruments for those applications is also growing. One critical parameter of water quality is the amount of total organic carbon (TOC). This work presents a system that uses the advantage of the increased oxidation power achieved with UV/O3 advanced oxidation process (AOP) for TOC measurement in combination with a significant miniaturization compared to the state of the art. The miniaturization is achieved by using polymer-electrolyte membrane (PEM) electrolysis cells for ozone generation in combination with UV-LEDs for irradiation of the measuring solution, as both components are significantly smaller than standard equipment. Conductivity measurement after oxidation is the measuring principle and measurements were carried out in the TOC range between 10 and 1000 ppb TOC. The suitability of the system for TOC measurement is demonstrated using the oxidation by ozonation combined with UV irradiation of defined concentrations of isopropyl alcohol (IPA).