Refine
H-BRS Bibliography
- yes (26) (remove)
Departments, institutes and facilities
- Fachbereich Angewandte Naturwissenschaften (26) (remove)
Document Type
- Doctoral Thesis (26) (remove)
Year of publication
Has Fulltext
- no (26)
Keywords
- Lignin (3)
- Antioxidans (2)
- Spektroskopie (2)
- ABTS (1)
- Additiv (1)
- Agarose (1)
- Analytik (1)
- Anoplophora glabripennis (1)
- Antioxidant capacity (1)
- Antioxidanz (1)
During space missions astronauts suffer from cardiovascular deconditioning, when they are exposed to microgravity conditions. Until now, no specific drugs are available for effective countermeasures, since the underlying mechanism is not completely understood. Endothelial cells (ECs) and smooth muscle cells (SMCs) play crucial roles in a variety of cardiovascular functions, many of which are regulated via P2 receptors. However, their function in ECs and SMCs under microgravity condition is still unknown. In this study, ECs and SMCs were isolated from bovine aorta and differentiated from human mesenchymal stem cells (hMSCs), respectively. Subsequently, the cells were verified based on specific markers. An altered P2 receptor expression pattern was detected during the commitment of hMSC towards ECs and SMCs. The administration of natural and artificial P2 receptor agonists and antagonists directly affected the differentiation process. By using EC growth medium as conditioned medium, a vessel cell model was created to culture SMCs and vice versa. Within this study, we were able to show for the first time that the expression of some P2 receptors were altered in ECs and SMCs grown for 24h under simulated microgravity conditions. On the other hand, in some P2 receptor expressions such as P2X7 conditioned medium compensated this change.
In conclusion, our data show that P2 receptors play an important functional role in hMSC differentiation towards ECs and SMCs. Since some P2 receptor artificial ligands are already used as drugs for patients with cardiovascular diseases, it is reasonable to assume that in the future they might be promising candidates for treating cardiovascular deconditioning.
Lignin ist bereits ein intensives Gebiet der Forschung, allerdings werden Verknüpfungen zwischen Quelle, Aufschlussmethode und Einsatz in der Literatur kaum beschrieben. In der vorliegenden Arbeit werden Lignine von verschiedenen Quellen (Weizenstroh, Buche, Nadelholz) und Aufschlussmethoden (AFEX, Wasserdampfaufschluss, Organosolv, Saure Hydrolyse) analytisch erfasst und hinsichtlich ihres Einsatzes in polymeren Materialien charakterisiert. Eine breite Auswahl an Methoden wurden eingesetzt, FT-IR- Spektroskopie, UV-Vis, 31P-NMR, GPC, Pyrolyse-GC/MS, sowie HPLC zur Bestimmung der Reinheit gemäß des NREL-Standard-Protokolls. Thermische Analysen, wie TGA und DSC zeigten Glasübergangstemperaturen um 120°C, sowie Zersetzungstemperaturen zwischen 340°C und 380°C. Die Ergebnisse weisen für das Organosolv-Buchenholz-Lignin hochreine Fraktionen auf, die bis dato noch nicht erreicht wurden. Die Ergebnisse dieser Arbeit identifizien die Organosolv-Buchenholz-Lignine als ein verwertbares Produkt im Hinblick auf die Anwendung in Polyurethanen sowie Phenol-Formaldehydharzen.
In this doctoral thesis the curing process of visible light-curing (VLC) dental composites and 3D printing rapid prototyping (RP) materials are investigated with the focus on dielectric analysis (DEA). This method is able to monitor the curing of resins in an alternating electric fringe field with adjustable frequencies and is often used for cure control of composites manufacturing in the aviation and automotive industry but hardly established in dental science or RP method development. It is capable of investigating very fast initiation and primary curing processes using high frequencies in the kHz-range. The aim of the Thesis is a better understanding of the curing processes with respect to curing parameters such as resin composition, viscosity, temperature, and for light-curing composites also light intensity and irradiation depth. Due to the nature of both dental and RP systems an application of specific experimental set-up had to be designed allowing for the generation of reproducible and valid results. Subsequently, different evaluation methods were developed to characterize the curing behavior of both material types. A special focus was paid to the determination of kinetic parameters from DEA measurements. Reaction rates of the curing of the corresponding thermosets were calculated and applied to the ion viscosity curves measured by DEA to evaluate reaction kinetic parameters. For the dental composites it could be clearly shown that the initial curing rate is directly proportional to light intensity and not to its square root as proposed by many others authors. A good description of the curing behaviour of 3DP RP materials was also achieved assuming a reaction order smaller than one. This data provides the base for the kinetic modeling of polymerization and curing processes proposed within the Thesis.
During the last 50 years, a broad range of visible light curing resin based composites (VLC RBC) was developed for restorative applications in dentistry. Correspondingly, the technologies of light curing units (LCU) have changed from UV to visible blue light, and there from quartz tungsten halogen over plasma arc to LED LCUs increasing their light intensity significantly. In this thesis, the influence of the curing conditions in terms of irradiance, exposure time and irradiance distribution of LCU on reaction kinetics as well as corresponding mechanical and viscoelastic properties were investigated.
Gegenstand dieser Arbeit sind Untersuchungen zur Detektion von verpackten Gefahrstoffen wie beispielsweise Explosivstoffen. Hierzu wird in einem ersten Schritt die Verpackung mittels Laserbohrens durchdrungen, um anschließend den nun freiliegenden Gefahrstoff nachweisen zu können. Dies geschieht einerseits durch eine lasergestützte Probenahme und anschließende Detektion mit gängigen chemisch-analytischen Verfahren sowie direkt bei der Wechselwirkung zwischen Laser und Gefahrstoff mittels Ramanspektroskopie. Zudem werden schnelle in situ-Techniken im Hinblick auf ihre Eignung zur Überwachung des Laserbohrprozesses untersucht. Hier werden kostengünstige und kompakte Sensortechniken (Messung der Prozessgase durch Halbleitergassensoren, Messung des Luftschalls mittels Kondensatormikrofon) mit aufwendigeren und komplexeren spektroskopischen Verfahren (Plasma- und Ramanspektroskopie) bewertend verglichen. Anhand ausgewählter Modellsysteme in verkleinertem Maßstab werden die unterschiedlichen Verfahren unter Verwendung gängiger Verpackungs- und Hüllenmaterialien sowie anhand ausgewählter Explosivstoffe charakterisiert. Für das Laserverfahren kommen gepulste Nd:YAG Laser mit unterschiedlichen Emissionswellenlängen zum Einsatz.
Im Rahmen der vorliegenden wissenschaftlichen Arbeit wurde das Potenzial der einfachen Halbleitergassensoren zum Einsatz in komplexen Fragestellungen erforscht. Ein im wahrsten Sinne des Wortes brandaktuelles Thema, das hier in den Fokus geraten ist, ist die Detektion explosionsfähiger Substanzen. 42547 – so hoch war die Anzahl der Terroranschläge im Zeitraum 2000 bis 2016, die unter Einsatz von energetischen Materialien begangen wurden. Bei mehr als der Hälfte waren Menschenopfer zu beklagen. Terrorismus ist eine Gefahr und neue explosionsfähige Stoffmischungen, deren Analysedaten in keiner Datenbank eines Detektors enthalten sind, bilden zurzeit ein enormes Bedrohungspotential - solche Gefahrstoffe sind mit etablierten bibliothekgestützten Verfahren schwer nachweisbar. In dieser Arbeit wurde ein bibliothekfrei arbeitender Detektor entwickelt, der schnell und verlässlich die Explosionsfähigkeit unbekannter Substanzen anhand der Auswertung ihrer Reaktionsverläufe bewerten konnte. Es wurde gezeigt, dass der Einsatz von Halbleitergassensoren in Kombination mit Photodioden und einem Drucksensor unter Voraussetzung der durchdachten Reaktionsführung und Anwendung von auf die Aufgabenstellung zugeschnittenen Auswertealgorithmen zielführend ist und eine extrem hohe Detektionsrate von 99,8% ermöglicht. Des Weiteren wurde ein einfacher Herstellungsweg für Halbleitergassensoren ausgehend von der vorhandenen Precursorbibliothek gefunden, der in Zukunft gezielte Manipulation der sensorischen Eigenschaften der Halbleitergassensoren durch Variieren des eingesetzten Precursors sowie der Sensorherstellungsparameter erlaubt. Die auf diesem Weg gefertigten Sensoren wurden in den entwickelten Detektor integriert und zeigten großes Potential neben bibliothekfreier Einschätzung der Explosionsfähigkeit einer unbekannten Substanz auch Aussagen über deren Identität treffen zu können.