Refine
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (94) (remove)
Document Type
- Article (44)
- Conference Object (34)
- Report (5)
- Doctoral Thesis (3)
- Patent (3)
- Contribution to a Periodical (2)
- Part of a Book (1)
- Conference Proceedings (1)
- Research Data (1)
Year of publication
Keywords
- Chemometrics (4)
- DNA typing (3)
- Raman spectroscopy (3)
- Classification (2)
- Cooperative Awareness Message (2)
- Discriminant analysis (2)
- Hyperspectral image (2)
- Intelligent Transport System (2)
- Principal Components Analysis (2)
- Privacy (2)
The human gut microbiota harbors untapped potential for biotechnological applications. Within the phylum of Bacteroidota, Phocaeicola vulgatus stands out as a promising candidate for sustainable production of key platform chemicals like succinate. However, genetic engineering of Phocaeicola sp. remains challenging due to its intricate molecular landscape. This study lays the groundwork for manipulating the central carbon pathways in Phocaeicola vulgatus, offering insights into overcoming genetic hurdles for increased succinate yields.
In this work, the surface reactions of the homemade explosive triacetone triperoxide on tungsten oxide (WO3) sensor surfaces are studied to obtain detailed information about the chemical reactions taking place. Semiconductor gas sensors based on WO3 nanopowders are therefore produced and characterized by scanning electron microscopy, X-ray diffraction, and Raman spectroscopy. To analyze the reaction mechanisms at the sensor surface, the sensor is monitored online under operation conditions using Raman spectroscopy, which allows to identify the temperature-dependent sensor reactions. By combining information from the Raman spectra with data on the changing resistivity of the underlying semiconductor, it is possible to establish a correlation between the adsorbed gas species and the physical properties of the WO3 layer. In the results, it is indicated that a Lewis acid–base reaction is the most likely mechanism for the increase in resistance observed at temperatures below 150 °C. In the results, at higher temperatures, the assumption of a radical mechanism that causes a decrease in resistance is supported.
Due to their user-friendliness and reliability, biometric systems have taken a central role in everyday digital identity management for all kinds of private, financial and governmental applications with increasing security requirements. A central security aspect of unsupervised biometric authentication systems is the presentation attack detection (PAD) mechanism, which defines the robustness to fake or altered biometric features. Artifacts like photos, artificial fingers, face masks and fake iris contact lenses are a general security threat for all biometric modalities. The Biometric Evaluation Center of the Institute of Safety and Security Research (ISF) at the University of Applied Sciences Bonn-Rhein-Sieg has specialized in the development of a near-infrared (NIR)-based contact-less detection technology that can distinguish between human skin and most artifact materials. This technology is highly adaptable and has already been successfully integrated into fingerprint scanners, face recognition devices and hand vein scanners. In this work, we introduce a cutting-edge, miniaturized near-infrared presentation attack detection (NIR-PAD) device. It includes an innovative signal processing chain and an integrated distance measurement feature to boost both reliability and resilience. We detail the device’s modular configuration and conceptual decisions, highlighting its suitability as a versatile platform for sensor fusion and seamless integration into future biometric systems. This paper elucidates the technological foundations and conceptual framework of the NIR-PAD reference platform, alongside an exploration of its potential applications and prospective enhancements.
Microorganisms not only contribute to the spoilage of food but can also cause illnesses through consumption. Consumer concerns and doubts about the shelf life of the products and the resulting enormous amounts of food waste have led to a demand for a rapid, robust, and non-destructive method for the detection of microorganisms, especially in the food sector. Therefore, a rapid and simple sampling method for the Raman- and infrared (IR)-microspectroscopic study of microorganisms associated with spoilage processes was developed. For subsequent evaluation pre-processing routines, as well as chemometric models for classification of spoilage microorganisms were developed. The microbiological samples are taken using a disinfectable sampling stamp and measured by microspectroscopy without the usual pre-treatments such as purification separation, washing, and centrifugation. The resulting complex multivariate data sets were pre-processed, reduced by principal component analysis, and classified by discriminant analysis. Classification of independent unlabeled test data showed that microorganisms could be classified at genus, species, and strain levels with an accuracy of 96.5 % (Raman) and 94.5 % (IR), respectively, despite large biological differences and novel sampling strategies. As bacteria are exposed to constantly changing conditions and their adaptation mechanisms may make them inaccessible to conventional measurement methods, the methods and models developed were investigated for their suitability for microorganisms exposed to stress. Compared to normal growth conditions, spectral changes in lipids, polysaccharides, nucleic acids, and proteins were observed in microorganisms exposed to stress. Models were developed to discriminate microorganisms, independent of the involvement of various stress factors and storage times. Classification of the investigated bacteria yielded accuracies of 97.6 % (Raman) and 96.6 % (IR), respectively, and a robust and meaningful model was developed to discriminate different microorganisms at the genus, species, and strain levels. The obtained results are very promising and show that the methods and models developed for the discrimination of microorganisms as well as the investigation of stress factors on microorganisms by means of Raman- and IR-microspectroscopy have the potential to be used, for example, in the food sector for the rapid determination of surface contamination.
Forensic DNA profiles are established by multiplex PCR amplification of a set of highly variable short tandem repeat (STR) loci followed by capillary electrophoresis (CE) as a means to assign alleles to PCR products of differential length. Recently, CE analysis of STR amplicons has been supplemented by high-throughput next generation sequencing (NGS) techniques that are able to detect isoalleles bearing sequence polymorphisms and allow for an improved analysis of degraded DNA. Several such assays have been commercialised and validated for forensic applications. However, these systems are cost-effective only when applied to high numbers of samples. We report here an alternative, cost-efficient shallow-sequence output NGS assay called maSTR assay that, in conjunction with a dedicated bioinformatics pipeline called SNiPSTR, can be implemented with standard NGS instrumentation. In a back-to-back comparison with a CE-based, commercial forensic STR kit, we find that for samples with low DNA content, with mixed DNA from different individuals, or containing PCR inhibitors, the maSTR assay performs equally well, and with degraded DNA is superior to CE-based analysis. Thus, the maSTR assay is a simple, robust and cost-efficient NGS-based STR typing method applicable for human identification in forensic and biomedical contexts.
The development of whole-genome amplification (WGA) techniques has opened up new avenues for genetic analysis and genome research, in particular by facilitating the genome-wide analysis of few or even single copies of genomic DNA, such as from single cells (prokaryotic or eukaryotic) or virions. Using WGA, the few copies of genomic DNA obtained from such entities are unspecifically amplified using PCR or PCR-related processes in order to obtain higher DNA quantities that can then be successfully analysed further.
A Fourier scatterometry setup is evaluated to recover the key parameters of optical phase gratings. Based on these parameters, systematic errors in the printing process of two-photon polymerization (TPP) gray-scale lithography three-dimensional printers can be compensated, namely tilt and curvature deviations. The proposed setup is significantly cheaper than a confocal microscope, which is usually used to determine calibration parameters for compensation of the TPP printing process. The grating parameters recovered this way are compared to those obtained with a confocal microscope. A clear correlation between confocal and scatterometric measurements is first shown for structures containing either tilt or curvature. The correlation is also shown for structures containing a mixture of tilt and curvature errors (squared Pearson coefficient r2 = 0.92). This compensation method is demonstrated on a TPP printer: a diffractive optical element printed with correction parameters obtained from Fourier scatterometry shows a significant reduction in noise as compared to the uncompensated system. This verifies the successful reduction of tilt and curvature errors. Further improvements of the method are proposed, which may enable the measurements to become more precise than confocal measurements in the future, since scatterometry is not affected by the diffraction limit.
P30 - Das Elektrospinnen von halbleitenden Zinndioxidfasern für die Detektion von Wasserstoff
(2022)
Das Ziel dieser Arbeit ist die Entwicklung von dünnen keramischen Fasern als halbleitendes Sensormaterial zum Nachweis von Wasserstoff, möglichst bei Zimmertemperatur. Die elektrische Leitfähigkeit halbleitender Metalloxide ändert sich durch die Einwirkung von oxidierenden und reduzierenden Gasen auf die Oberfläche des Metalloxids. Dieser Effekt kann zur Messung der Gaskonzentration genutzt werden. Die Reaktion von Zinn(IV)-oxid mit Wasserstoff basiert auf der Reduktion des Zinn(IV)-oxids zum Zinn, wobei die Elektronen des Zinn(IV)-oxids im metallischen Zinn verbleiben und dort im nicht gebundenen Zustand zu einer Leitfähigkeitserhöhung beitragen. Die Reaktion des Wasserstoffes kann sowohl mit den Sauerstoffatomen des Oxids als auch mit adsorbierten Sauerstoffatomen an der Oxidoberfläche stattfinden.[ 6] Da die Reaktionen an der Oberfläche des Oxids stattfinden, sollten Sensoren mit einer großen Oberfläche im Vergleich zu metalloxidischen Bulkmaterialien eine höhere Empfindlichkeit aufweisen. [3] Die Verwendung von Fasern anstelle von Dünn- oder Dickschichten führt dabei zu einer besseren Sensitivität gegenüber Gasen.
With the increasing demand for ultrapure water in the pharmaceutical and semiconductor industry, the need for precise measuring instruments for those applications is also growing. One critical parameter of water quality is the amount of total organic carbon (TOC). This work presents a system that uses the advantage of the increased oxidation power achieved with UV/O3 advanced oxidation process (AOP) for TOC measurement in combination with a significant miniaturization compared to the state of the art. The miniaturization is achieved by using polymer-electrolyte membrane (PEM) electrolysis cells for ozone generation in combination with UV-LEDs for irradiation of the measuring solution, as both components are significantly smaller than standard equipment. Conductivity measurement after oxidation is the measuring principle and measurements were carried out in the TOC range between 10 and 1000 ppb TOC. The suitability of the system for TOC measurement is demonstrated using the oxidation by ozonation combined with UV irradiation of defined concentrations of isopropyl alcohol (IPA).