Refine
H-BRS Bibliography
- yes (68) (remove)
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (68) (remove)
Document Type
- Conference Object (33)
- Article (19)
- Report (5)
- Doctoral Thesis (3)
- Patent (3)
- Contribution to a Periodical (2)
- Part of a Book (1)
- Conference Proceedings (1)
- Research Data (1)
Year of publication
Has Fulltext
- no (68) (remove)
Keywords
- Chemometrics (3)
- Cooperative Awareness Message (2)
- Discriminant analysis (2)
- Hyperspectral image (2)
- Intelligent Transport System (2)
- Principal Components Analysis (2)
- Privacy (2)
- Pseudonym Concept (2)
- Raman microscopy (2)
- Raman spectroscopy (2)
Die Detektion von Explosivstoffen stellt ein zentrales Feld der zivilen Sicherheitsforschung dar. Eine besondere Herausforderung liegt hierbei in dem Nachweis verpackter Substanzen, wie es bei Unkonventionellen Spreng- und Brandvorrichtung (USBV) häufig der Fall ist. Derzeit eingesetzte Verfahren arbeiten meist mit bildgebenden Techniken, durch die sich ein Anfangsverdacht ergibt. Der tatsächliche chemische Inhalt der USBV lässt sich jedoch nicht exakt ermitteln. Eine genaue Beurteilung der Gefährdung durch solche Substanzen ist allerdings von großer Bedeutung, insbesondere wenn die Entschärfung des Objekts in bewohntem Gebiet stattfinden muss. In der vorliegenden Arbeit wird ein Verfahren vorgestellt, das sich als Verifikationsverfahren bei bestehendem Anfangsverdacht gezielt einsetzen lässt. Hierzu wird mittels Laserbohrtechnik zunächst die äußere Hülle des zu untersuchenden Gegenstandes durchdrungen. Anschließend finden eine lasergestützte Probenahme des Inhalts sowie die Detektion unter Verwendung geeigneter Analysemöglichkeiten statt. Der Bohr- und Probenahmefortschritt wird über verschiedene spektroskopische und sensorische Verfahren begleitend überwacht. Zukünftig soll das System abstandsfähig auf Entschärfungsrobotern eingesetzt werden.
Vorrichtung zur Authentifikation einer Person anhand mindestens eines biometrischen Parameters
(2008)
Die Vorrichtung zur Authentifikation einer Person anhand mindestens eines biometrischen Parameters, insbesondere anhand eines Fingerabdrucks, ist versehen mit einem Biometrie-Detektor (20) zur Detektion eines biometrischen Parameters, einem Haut-Detektor (24) zur berührungslosen Erkennung lebender menschlicher Haut innerhalb eines Erfassungsbereichs. Der Haut-Detektor (24) weist mindestens eine Gruppe aus mindestens einer Strahlungseinheit (26, 28) und mindestens einer Empfangseinheit (30) auf. Die mindestens eine Strahlungseinheit (26, 28) gibt in Richtung auf den Erfassungsbereich Strahlung bei mindestens zwei unterschiedlichen Wellenlängen im Wellenlängenbereich zwischen 400 nm und 1500 nm ab, wobei mindestens eine der Wellenlängen (26, 28) im Wellenlängenbereich von 900 nm bis 1500 nm liegt und die mindestens eine Empfangseinheit (30) aus dem Erfassungsbereich reflektierte Strahlung empfängt. Ferner ist die Vorrichtung versehen mit einer mit dem Biometer-Detektor (20) und dem Haut-Detektor (24) verbundenen Signalauswerteeinheit (22) zur Auswertung der Intensität der von der Empfangseinheit (30) empfangenen reflektierten Strahlungen der Strahlungseinheit (26, 28). In der Signalauswerteeinheit (22) ist anhand der Intensitäten der von der Empfangseinheit (30) empfangenen reflektierten Strahlungen der Strahlungseinheit (26, 28) bei den zwei unterschiedlichen Wellenlängen ermittelbar, ob der Haut-Detektor lebende menschliche Haut erkennt.
A deployment of the Vehicle-to-Vehicle communication technology according to ETSI is in preparation in Europe. Currently, a Public Key Infrastructure policy for Intelligent Transport Systems in Europe is in discussion to enable V2V communication. This policy set aside two classes of keys and certificates for ITS vehicle stations: long term authentication keys and pseudonymous keys and certificates. We show that from our point of view the periodic sent Cooperative Awareness Messages with extensive data have technical limitations and together with the pseudonym concept cause privacy problems.
At previous SIAS conferences, we presented a novel opto-electronic safety sensor system for skin detection at circular saws jointly developed with the Institute for Occupational Safety and Health of the German Social Accident Insurance (IFA). This work now presents the development results of our consecutive research on a prototype of a sensor system for more general production machine applications including robot workplaces. The system uses offthe shelf LEDs and photodiodes in combination with dedicated optics and a microcontroller system to implement a so-called spectral light curtain.
The device (10) has a handrail (18) provided with an optical contactless monitoring device formed as an active sensor system, where the monitoring device is arranged in a region of a guide (14) of the handrail at a front base (16) of an escalator (12) or a moving pavement. The monitoring device has two transmission paths (28, 30) with wavelength bands that are different from each other, where one of the paths includes the handrail. Ratio or difference between signals of the paths is used for recognizing foreign bodies e.g. hands of adults and children.
Microcontroller-based sensor systems offer great opportunities for the implementation of safety features for potentially dangerous machinery. However, in general they are difficult to assess with regard to their reliability and failure rate. This paper describes the safety assessment of hardware and software of a new and innovative sensor system. The hardware is assessed by standardized methods according to norm EN ISO 13849-1, while the use of model checking is presented as an approach to solve the problem of validating the software.
Microorganisms not only contribute to the spoilage of food but can also cause illnesses through consumption. Consumer concerns and doubts about the shelf life of the products and the resulting enormous amounts of food waste have led to a demand for a rapid, robust, and non-destructive method for the detection of microorganisms, especially in the food sector. Therefore, a rapid and simple sampling method for the Raman- and infrared (IR)-microspectroscopic study of microorganisms associated with spoilage processes was developed. For subsequent evaluation pre-processing routines, as well as chemometric models for classification of spoilage microorganisms were developed. The microbiological samples are taken using a disinfectable sampling stamp and measured by microspectroscopy without the usual pre-treatments such as purification separation, washing, and centrifugation. The resulting complex multivariate data sets were pre-processed, reduced by principal component analysis, and classified by discriminant analysis. Classification of independent unlabeled test data showed that microorganisms could be classified at genus, species, and strain levels with an accuracy of 96.5 % (Raman) and 94.5 % (IR), respectively, despite large biological differences and novel sampling strategies. As bacteria are exposed to constantly changing conditions and their adaptation mechanisms may make them inaccessible to conventional measurement methods, the methods and models developed were investigated for their suitability for microorganisms exposed to stress. Compared to normal growth conditions, spectral changes in lipids, polysaccharides, nucleic acids, and proteins were observed in microorganisms exposed to stress. Models were developed to discriminate microorganisms, independent of the involvement of various stress factors and storage times. Classification of the investigated bacteria yielded accuracies of 97.6 % (Raman) and 96.6 % (IR), respectively, and a robust and meaningful model was developed to discriminate different microorganisms at the genus, species, and strain levels. The obtained results are very promising and show that the methods and models developed for the discrimination of microorganisms as well as the investigation of stress factors on microorganisms by means of Raman- and IR-microspectroscopy have the potential to be used, for example, in the food sector for the rapid determination of surface contamination.