Refine
H-BRS Bibliography
- yes (93) (remove)
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (93) (remove)
Document Type
- Article (43)
- Conference Object (34)
- Report (5)
- Doctoral Thesis (3)
- Patent (3)
- Contribution to a Periodical (2)
- Part of a Book (1)
- Conference Proceedings (1)
- Research Data (1)
Year of publication
Keywords
- Chemometrics (4)
- DNA typing (3)
- Raman spectroscopy (3)
- Classification (2)
- Cooperative Awareness Message (2)
- Discriminant analysis (2)
- Hyperspectral image (2)
- Intelligent Transport System (2)
- Principal Components Analysis (2)
- Privacy (2)
- Pseudonym Concept (2)
- Raman microscopy (2)
- Raman-microspectroscopy (2)
- SERS (2)
- Short tandem repeat (STR) (2)
- Skin detection (2)
- TNT (2)
- Vehicular Ad hoc Networks (2)
- automated sensor-screening (2)
- biometrics (2)
- classification (2)
- discriminant analysis (2)
- food-related bacteria (2)
- image fusion (2)
- machine learning (2)
- optical sensor (2)
- pansharpening (2)
- photonic sensing (2)
- semiconducting metal oxide gas sensor array (2)
- stress response (2)
- AOP (1)
- Agglomerative Hierarchical Cluster Analysis (1)
- Amplifiers (1)
- Anoplophora glabripennis (1)
- AuNPs (1)
- Bacteria (1)
- Bakterien (1)
- Chemical imaging (1)
- Chemicals (1)
- Chemometrie (1)
- Chiral-nematischer Flüssigkristall (1)
- Chromatographische Analyse, Elektrophorese (1)
- Chromatography (1)
- Circular saws (1)
- Collaborating industrial robots (1)
- DNA profile (1)
- Defense and security (1)
- Degraded DNA (1)
- Diodes (1)
- E. coli (1)
- Echtzeitüberwachung (1)
- Embedded system (1)
- Engineering (1)
- Explosives (1)
- Fiber-optic probe (1)
- Flüssigkristalline Polymere (1)
- Forensic genetics (1)
- Forensic genomics (1)
- Fourier scatterometry (1)
- Frequenzauswertung (1)
- Functional safety (1)
- Fährverkehr (1)
- GC/MS (1)
- Gassensor (1)
- Geruchssinn (1)
- Hand injuries (1)
- Heterogenes Sensorsystem (1)
- Homemade explosives (1)
- IED (1)
- IR microspectroscopy (1)
- IR-microspectroscopy (1)
- Infrared (1)
- Infrarot (1)
- Koaxiales Elektrospinnen (1)
- Kriminalistik (1)
- Laser drilling (1)
- Laser induced breakdown spectroscopy (1)
- Laserbohren (1)
- Lasermaterialbearbeitung (1)
- Light curtain (1)
- Liquid crystal (1)
- MAP (1)
- MOX gas sensors (1)
- Meat-associated Microorganisms (1)
- Metals (1)
- Microorganisms (1)
- Mobile explosive identification (1)
- Multimodal hyperspectral data (1)
- NIR (1)
- NIR-point sensor (1)
- Next Generation Sequencing (NGS) (1)
- O3/UV (1)
- OCT (1)
- Optische Gassensorik (1)
- PAD (1)
- PCR inhibitors (1)
- Pathogenic Bacteria (1)
- Pattern recognition (1)
- Poultry (1)
- Poultry meat (1)
- Poultry spoilage (1)
- Primary explosives (1)
- Principal component analysis (1)
- Probabilistic methods (1)
- Propellants (1)
- Protective system (1)
- Ps. fluorescens (1)
- Raman (1)
- Raman Spectroscopy (1)
- Rapid method (1)
- Safety guard (1)
- Sensorik (1)
- Sensors (1)
- Sicherheitsmaßnahme (1)
- Smart InGaAs camera-system (1)
- Spectroscopy (1)
- Spectroscropy (1)
- Spektroskopie (1)
- Spoilage (1)
- Spoilage bacteria (1)
- Spürhund (1)
- Supervised classification (1)
- Support vector machines (1)
- TD-GC/MS (1)
- TOC (1)
- Telogen hair (1)
- TiO2-coatings (1)
- Ultrasonic array (1)
- VOC (1)
- Vehicle-2-Vehicle Communication (1)
- Vehicle-to-Vehicle Communication (1)
- Vibrational microspectroscopy (1)
- Volatile organic compounds (1)
- Whole genome amplification (1)
- X-STR (1)
- Y-STR (1)
- ambulatory monitoring (1)
- analog/digital signal processing (1)
- authentication (1)
- automatic measurement validation (1)
- bacteria (1)
- bioinformatics (1)
- brightfield microscopy (1)
- camera-based person detection (1)
- chemometrics (1)
- chemosensing (1)
- chiral-nematic (1)
- cholesteric liquid crystals (1)
- cholesteric phase (1)
- coaxial electrospinning (1)
- coffee ring effect (1)
- core-sheath fibers (1)
- decision tree learning (1)
- degraded DNA (1)
- detection (1)
- displacement measurement (1)
- electrospinning (1)
- encapsulation (1)
- estimation (1)
- feature (1)
- fingerprint (1)
- food safety (1)
- forensic (1)
- forensic genetics (1)
- gas sensor (1)
- grating reconstruction (1)
- halogen bonding (1)
- helical twisting power (1)
- high degree of diagnostic coverage and reliability (1)
- high diagnostic coverage and reliability (1)
- high dynamic range resistance readout (1)
- high-throughput sequencing (1)
- holography (1)
- human-robot collaboration (1)
- hydrogen bonding (1)
- industrial robots (1)
- light curtains (1)
- liquid crystal (1)
- low molecular weight (1)
- massive parallel sequencing (1)
- metal-oxide-semiconductor gas sensors (1)
- micromanipulation (1)
- mobile Explosivstoffdetektion (1)
- multi causal strain (1)
- multi-channel power sourcing (1)
- multiresolution analysis (1)
- near infrared (1)
- near-infrared (1)
- next generation sequencing (1)
- nitrogen dioxide (1)
- non-woven fiber mats (1)
- operando Raman spectroscopies (1)
- optical coherence tomography (1)
- optical safeguard sensor (1)
- optical triangulation (1)
- opto-electronic protective device (1)
- ozonation (1)
- physical activity (1)
- physiological monitoring (1)
- presentation attack detection (1)
- presentation attack detection (PAD) (1)
- primäre Explosivstoffe (1)
- prioritizable ranking (1)
- sensor resilience (1)
- sexual assault (1)
- short tandem repeat (1)
- short tandem repeat (STR) (1)
- signal processing algorithm (1)
- skin detection (1)
- slope based signature (1)
- sperm cell (1)
- strain (1)
- stress (1)
- supramolecular liquid crystals (1)
- thermosensing (1)
- time series analysis (1)
- transmission phase gratings (1)
- triacetone triperoxides (1)
- tunable pitch (1)
- tungsten oxides (1)
- two-photon polymerization (1)
- ultrapure water (1)
- ultrasonic sensor (1)
- volatile organic compound (VOC) sensing (1)
- wearable technology (1)
- whole genome amplification (WGA) (1)
Forensic DNA profiles are established by multiplex PCR amplification of a set of highly variable short tandem repeat (STR) loci followed by capillary electrophoresis (CE) as a means to assign alleles to PCR products of differential length. Recently, CE analysis of STR amplicons has been supplemented by high-throughput next generation sequencing (NGS) techniques that are able to detect isoalleles bearing sequence polymorphisms and allow for an improved analysis of degraded DNA. Several such assays have been commercialised and validated for forensic applications. However, these systems are cost-effective only when applied to high numbers of samples. We report here an alternative, cost-efficient shallow-sequence output NGS assay called maSTR assay that, in conjunction with a dedicated bioinformatics pipeline called SNiPSTR, can be implemented with standard NGS instrumentation. In a back-to-back comparison with a CE-based, commercial forensic STR kit, we find that for samples with low DNA content, with mixed DNA from different individuals, or containing PCR inhibitors, the maSTR assay performs equally well, and with degraded DNA is superior to CE-based analysis. Thus, the maSTR assay is a simple, robust and cost-efficient NGS-based STR typing method applicable for human identification in forensic and biomedical contexts.
The application of Raman and infrared (IR) microspectroscopy is leading to hyperspectral data containing complementary information concerning the molecular composition of a sample. The classification of hyperspectral data from the individual spectroscopic approaches is already state-of-the-art in several fields of research. However, more complex structured samples and difficult measuring conditions might affect the accuracy of classification results negatively and could make a successful classification of the sample components challenging. This contribution presents a comprehensive comparison in supervised pixel classification of hyperspectral microscopic images, proving that a combined approach of Raman and IR microspectroscopy has a high potential to improve classification rates by a meaningful extension of the feature space. It shows that the complementary information in spatially co-registered hyperspectral images of polymer samples can be accessed using different feature extraction methods and, once fused on the feature-level, is in general more accurately classifiable in a pattern recognition task than the corresponding classification results for data derived from the individual spectroscopic approaches.
Durch Dotierung eines nematischen Flüssigkristalles mit einer chiralen Substanz wird eine helikal strukturierte Phase induziert, die in der Lage ist, einfallendes Licht wellenlängenselektiv zu reflektieren. Bei der Reaktion des Dotiermittels mit einem gasförmigen Analyten verändern sich die Ganghöhe dieser Struktur und damit die reflektierte Wellenlänge. Liegt diese im Bereich des sichtbaren Lichts, ist eine Farbänderung mit dem menschlichen Auge zu beobachten. Es ist dabei sinnvoll den Flüssigkristall z.B. in einem Polymer einzukapseln, um ihn vor mechanischen Einflüssen und Umwelteinflüssen zu schützen. Eine Möglichkeit zur Einkapselung ist das koaxiale Elektrospinnen. Vorteile sind unter anderem die Realisierung einer großen Oberfläche und einer sehr geringen Wanddicke der schützenden Schale, die die Diffusion von Gasen durch die Wand hindurch ermöglicht. Um die Funktionsfähigkeit eines solchen Sensors zu testen, wurde ein CO2-sensitiver Flüssigkristall verwendet. Dieser wurde in eine Schale aus Polyvinylpyrrolidon (PVP) versponnen und die Reaktion mit CO2 spektroskopisch analysiert.
Optical gas sensors based on chiral-nematic liquid crystals (N* LCs) forming one-dimensional photonic crystals do not require electrical energy and have a considerable potential to supplement established types of sensors. A chiral-nematic phase with tunable selective reflection is induced in a nematic host LC by adding reactive chiral dopants. The selective chemical reaction between dopant and analyte is capable to vary the pitch length (the lattice constant) of the soft, self-assembled, one-dimensional photonic crystal. The progress of the ongoing chemical reaction can be observed even by naked eye because the color of the samples varies. In this work, we encapsulate the responsive N* LC in microscale polyvinylpyrrolidone (PVP) fibers via coaxial electrospinning. The sensor is, thus, given a solid form and has an improved stability against nonavoidable environmental influences. The reaction behavior of encapsulated and nonencapsulated N* LC toward a gaseous analyte is compared, systematically. Making use of the encapsulation is an important step to improve the applicability.
Due to their user-friendliness and reliability, biometric systems have taken a central role in everyday digital identity management for all kinds of private, financial and governmental applications with increasing security requirements. A central security aspect of unsupervised biometric authentication systems is the presentation attack detection (PAD) mechanism, which defines the robustness to fake or altered biometric features. Artifacts like photos, artificial fingers, face masks and fake iris contact lenses are a general security threat for all biometric modalities. The Biometric Evaluation Center of the Institute of Safety and Security Research (ISF) at the University of Applied Sciences Bonn-Rhein-Sieg has specialized in the development of a near-infrared (NIR)-based contact-less detection technology that can distinguish between human skin and most artifact materials. This technology is highly adaptable and has already been successfully integrated into fingerprint scanners, face recognition devices and hand vein scanners. In this work, we introduce a cutting-edge, miniaturized near-infrared presentation attack detection (NIR-PAD) device. It includes an innovative signal processing chain and an integrated distance measurement feature to boost both reliability and resilience. We detail the device’s modular configuration and conceptual decisions, highlighting its suitability as a versatile platform for sensor fusion and seamless integration into future biometric systems. This paper elucidates the technological foundations and conceptual framework of the NIR-PAD reference platform, alongside an exploration of its potential applications and prospective enhancements.
Polymer fibers with liquid crystals (LCs) in the core have potential as autonomous sensors of airborne volatile organic compounds (VOCs), with a high surface-to-volume ratio enabling fast and sensitive response and an attractive non-woven textile form factor. We demonstrate their ability to continuously and quantitatively measure the concentration of toluene, cyclohexane, and isopropanol as representative VOCs, via the impact of each VOC on the LC birefringence. The response is fully reversible and repeatable over several cycles, the response time can be as low as seconds, and high sensitivity is achieved when the operating temperature is near the LC-isotropic transition temperature. We propose that a broad operating temperature range can be realized by combining fibers with different LC mixtures, yielding autonomous VOC sensors suitable for integration in apparel or in furniture that can compete with existing consumer-grade electronic VOC sensors in terms of sensitivity and response speed.
The use of manually fed machines (e.g. table saws) bares risks of injury that are clearly above the average level of other high risk workplaces.
The wide use of such machines causes severe problems for occupational safety and implies high costs for medical treatments and accident annuities.
This thesis presents a new concept of a multispectral sensor to monitor an area in front of a danger zone to detect the user’s limbs and trigger safeguarding measures to prevent an accident in time.
The sensor concept realizes a contact-free material classification, which comprises the development of a system design and specific safety requirements with respect to international safety standards.
Furthermore, a prototypical implementation using four wavebands, which were determined for skin detection through an analysis of reflectance spectra acquired specifically for this purpose, was built.
Vorrichtung zur Authentifikation einer Person anhand mindestens eines biometrischen Parameters
(2008)
Die Vorrichtung zur Authentifikation einer Person anhand mindestens eines biometrischen Parameters, insbesondere anhand eines Fingerabdrucks, ist versehen mit einem Biometrie-Detektor (20) zur Detektion eines biometrischen Parameters, einem Haut-Detektor (24) zur berührungslosen Erkennung lebender menschlicher Haut innerhalb eines Erfassungsbereichs. Der Haut-Detektor (24) weist mindestens eine Gruppe aus mindestens einer Strahlungseinheit (26, 28) und mindestens einer Empfangseinheit (30) auf. Die mindestens eine Strahlungseinheit (26, 28) gibt in Richtung auf den Erfassungsbereich Strahlung bei mindestens zwei unterschiedlichen Wellenlängen im Wellenlängenbereich zwischen 400 nm und 1500 nm ab, wobei mindestens eine der Wellenlängen (26, 28) im Wellenlängenbereich von 900 nm bis 1500 nm liegt und die mindestens eine Empfangseinheit (30) aus dem Erfassungsbereich reflektierte Strahlung empfängt. Ferner ist die Vorrichtung versehen mit einer mit dem Biometer-Detektor (20) und dem Haut-Detektor (24) verbundenen Signalauswerteeinheit (22) zur Auswertung der Intensität der von der Empfangseinheit (30) empfangenen reflektierten Strahlungen der Strahlungseinheit (26, 28). In der Signalauswerteeinheit (22) ist anhand der Intensitäten der von der Empfangseinheit (30) empfangenen reflektierten Strahlungen der Strahlungseinheit (26, 28) bei den zwei unterschiedlichen Wellenlängen ermittelbar, ob der Haut-Detektor lebende menschliche Haut erkennt.
In this paper, we introduce an optical sensor system, which is integrated into an industrial push-button. The sensor allows to classify the type of material that is in contact with the button when pressed into different material categories on the basis of the material's so called "spectral signature". An approach for a safety sensor system at circular table saws on the same base has been introduced previously on SIAS-2007. This contactless working sensor is able to distinguish reliably between skin, textiles, leather and various other kinds of materials. A typical application for this intelligent push-button is the use at possibly dangerous machines, whose operating instructions include either the prohibition or the obligation to wear gloves during the work at the machine. An exemple of machines at which no gloves are allowed are pillar drilling machines, because of the risk of getting caught in the drill chuck and being turned in by the machine. In many cases this causes very serious hand injuries. Depending on the application needs, the sensor system integrated into the push-button can be configured flexibly by software to prevent the operator from accidentally starting a machine with or without gloves, which can decrease the risk of severe accidents significantly. Especially two-hand controls are incentive to manipulation for easier handling. By equipping both push-buttons of a two-hand control with material classification properties, the user is forced to operate the controls with his bare fingers. That limitation disallows the manipulation of a two-hand control by a simple rodding device.
With the increasing demand for ultrapure water in the pharmaceutical and semiconductor industry, the need for precise measuring instruments for those applications is also growing. One critical parameter of water quality is the amount of total organic carbon (TOC). This work presents a system that uses the advantage of the increased oxidation power achieved with UV/O3 advanced oxidation process (AOP) for TOC measurement in combination with a significant miniaturization compared to the state of the art. The miniaturization is achieved by using polymer-electrolyte membrane (PEM) electrolysis cells for ozone generation in combination with UV-LEDs for irradiation of the measuring solution, as both components are significantly smaller than standard equipment. Conductivity measurement after oxidation is the measuring principle and measurements were carried out in the TOC range between 10 and 1000 ppb TOC. The suitability of the system for TOC measurement is demonstrated using the oxidation by ozonation combined with UV irradiation of defined concentrations of isopropyl alcohol (IPA).
A series of reactive binaphthyl‐diimine‐based dopants is prepared and investigated with respect to their potential for the chiral induction of structural coloration in nematic liquid crystal mixture E7 and the selective photonic sensing of nitrogen dioxide (NO2). Studies of the helical twisting power (HTP) in 4‐cyano‐4′‐pentylbiphenyl (5CB) reveal HTP values as high as 375 µm‐1 and the tremendous impact of structural compatibility and changes of the dihedral binaphthyl angle on the efficiency of the chiral transfer. Detailed investigation of the sensing capabilities of the systems reveals an extraordinarily high selectivity for NO2 and a response to concentrations as low as 100 ppm. The systems show a direct response to the analyte gas leading to a concentration‐dependent shift of the reflectance wavelength of up to several hundred nanometers. Incorporation of copper ions remarkably improves the sensor's properties in terms of sensitivity and selectivity, enabling the tailored tweaking of the system's properties.
Persons entering the working range of industrial robots are exposed to a high risk of collision with moving parts of the system, potentially causing severe injuries. Conventional systems, which restrict the access to this area, range from walls and fences to light barriers and other vision based protective devices (VBPD). None of these systems allow to distinguish between humans and workpieces in a safe and reliable manner. In this work, a new approach is investigated, which uses an active near-infrared (NIR) camera system with advanced capabilities of skin detection to distinguish humans from workpieces based on characteristic spectral signatures. This approach allows to implement more intelligent muting processes and at the same time increases the safety of persons working close to the robots. The conceptual integration of such a camera system into a VBPD and the enhancement of person detection methods through skin detection are described and evaluated in this paper. Based upon this work, next steps could be the development of multimodal sensor systems to safeguard working ranges of collaborating robots using the described camera system.
The detection of human skin in images is a very desirable feature for applications such as biometric face recognition, which is becoming more frequently used for, e.g., automated border or access control. However, distinguishing real skin from other materials based on imagery captured in the visual spectrum alone and in spite of varying skin types and lighting conditions can be dicult and unreliable. Therefore, spoofing attacks with facial disguises or masks are still a serious problem for state of the art face recognition algorithms. This dissertation presents a novel approach for reliable skin detection based on spectral remission properties in the short-wave infrared (SWIR) spectrum and proposes a cross-modal method that enhances existing solutions for face verification to ensure the authenticity of a face even in the presence of partial disguises or masks. Furthermore, it presents a reference design and the necessary building blocks for an active multispectral camera system that implements this approach, as well as an in-depth evaluation. The system acquires four-band multispectral images within T = 50ms. Using a machine-learning-based classifier, it achieves unprecedented skin detection accuracy, even in the presence of skin-like materials used for spoofing attacks. Paired with a commercial face recognition software, the system successfully rejected all evaluated attempts to counterfeit a foreign face.
Microcontroller-based sensor systems offer great opportunities for the implementation of safety features for potentially dangerous machinery. However, in general they are difficult to assess with regard to their reliability and failure rate. This paper describes the safety assessment of hardware and software of a new and innovative sensor system. The hardware is assessed by standardized methods according to norm EN ISO 13849-1, while the use of model checking is presented as an approach to solve the problem of validating the software.