Refine
H-BRS Bibliography
- yes (93) (remove)
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (93) (remove)
Document Type
- Article (43)
- Conference Object (34)
- Report (5)
- Doctoral Thesis (3)
- Patent (3)
- Contribution to a Periodical (2)
- Part of a Book (1)
- Conference Proceedings (1)
- Research Data (1)
Year of publication
Keywords
- Chemometrics (4)
- DNA typing (3)
- Raman spectroscopy (3)
- Classification (2)
- Cooperative Awareness Message (2)
- Discriminant analysis (2)
- Hyperspectral image (2)
- Intelligent Transport System (2)
- Principal Components Analysis (2)
- Privacy (2)
- Pseudonym Concept (2)
- Raman microscopy (2)
- Raman-microspectroscopy (2)
- SERS (2)
- Short tandem repeat (STR) (2)
- Skin detection (2)
- TNT (2)
- Vehicular Ad hoc Networks (2)
- automated sensor-screening (2)
- biometrics (2)
- classification (2)
- discriminant analysis (2)
- food-related bacteria (2)
- image fusion (2)
- machine learning (2)
- optical sensor (2)
- pansharpening (2)
- photonic sensing (2)
- semiconducting metal oxide gas sensor array (2)
- stress response (2)
- AOP (1)
- Agglomerative Hierarchical Cluster Analysis (1)
- Amplifiers (1)
- Anoplophora glabripennis (1)
- AuNPs (1)
- Bacteria (1)
- Bakterien (1)
- Chemical imaging (1)
- Chemicals (1)
- Chemometrie (1)
- Chiral-nematischer Flüssigkristall (1)
- Chromatographische Analyse, Elektrophorese (1)
- Chromatography (1)
- Circular saws (1)
- Collaborating industrial robots (1)
- DNA profile (1)
- Defense and security (1)
- Degraded DNA (1)
- Diodes (1)
- E. coli (1)
- Echtzeitüberwachung (1)
- Embedded system (1)
- Engineering (1)
- Explosives (1)
- Fiber-optic probe (1)
- Flüssigkristalline Polymere (1)
- Forensic genetics (1)
- Forensic genomics (1)
- Fourier scatterometry (1)
- Frequenzauswertung (1)
- Functional safety (1)
- Fährverkehr (1)
- GC/MS (1)
- Gassensor (1)
- Geruchssinn (1)
- Hand injuries (1)
- Heterogenes Sensorsystem (1)
- Homemade explosives (1)
- IED (1)
- IR microspectroscopy (1)
- IR-microspectroscopy (1)
- Infrared (1)
- Infrarot (1)
- Koaxiales Elektrospinnen (1)
- Kriminalistik (1)
- Laser drilling (1)
- Laser induced breakdown spectroscopy (1)
- Laserbohren (1)
- Lasermaterialbearbeitung (1)
- Light curtain (1)
- Liquid crystal (1)
- MAP (1)
- MOX gas sensors (1)
- Meat-associated Microorganisms (1)
- Metals (1)
- Microorganisms (1)
- Mobile explosive identification (1)
- Multimodal hyperspectral data (1)
- NIR (1)
- NIR-point sensor (1)
- Next Generation Sequencing (NGS) (1)
- O3/UV (1)
- OCT (1)
- Optische Gassensorik (1)
- PAD (1)
- PCR inhibitors (1)
- Pathogenic Bacteria (1)
- Pattern recognition (1)
- Poultry (1)
- Poultry meat (1)
- Poultry spoilage (1)
- Primary explosives (1)
- Principal component analysis (1)
- Probabilistic methods (1)
- Propellants (1)
- Protective system (1)
- Ps. fluorescens (1)
- Raman (1)
- Raman Spectroscopy (1)
- Rapid method (1)
- Safety guard (1)
- Sensorik (1)
- Sensors (1)
- Sicherheitsmaßnahme (1)
- Smart InGaAs camera-system (1)
- Spectroscopy (1)
- Spectroscropy (1)
- Spektroskopie (1)
- Spoilage (1)
- Spoilage bacteria (1)
- Spürhund (1)
- Supervised classification (1)
- Support vector machines (1)
- TD-GC/MS (1)
- TOC (1)
- Telogen hair (1)
- TiO2-coatings (1)
- Ultrasonic array (1)
- VOC (1)
- Vehicle-2-Vehicle Communication (1)
- Vehicle-to-Vehicle Communication (1)
- Vibrational microspectroscopy (1)
- Volatile organic compounds (1)
- Whole genome amplification (1)
- X-STR (1)
- Y-STR (1)
- ambulatory monitoring (1)
- analog/digital signal processing (1)
- authentication (1)
- automatic measurement validation (1)
- bacteria (1)
- bioinformatics (1)
- brightfield microscopy (1)
- camera-based person detection (1)
- chemometrics (1)
- chemosensing (1)
- chiral-nematic (1)
- cholesteric liquid crystals (1)
- cholesteric phase (1)
- coaxial electrospinning (1)
- coffee ring effect (1)
- core-sheath fibers (1)
- decision tree learning (1)
- degraded DNA (1)
- detection (1)
- displacement measurement (1)
- electrospinning (1)
- encapsulation (1)
- estimation (1)
- feature (1)
- fingerprint (1)
- food safety (1)
- forensic (1)
- forensic genetics (1)
- gas sensor (1)
- grating reconstruction (1)
- halogen bonding (1)
- helical twisting power (1)
- high degree of diagnostic coverage and reliability (1)
- high diagnostic coverage and reliability (1)
- high dynamic range resistance readout (1)
- high-throughput sequencing (1)
- holography (1)
- human-robot collaboration (1)
- hydrogen bonding (1)
- industrial robots (1)
- light curtains (1)
- liquid crystal (1)
- low molecular weight (1)
- massive parallel sequencing (1)
- metal-oxide-semiconductor gas sensors (1)
- micromanipulation (1)
- mobile Explosivstoffdetektion (1)
- multi causal strain (1)
- multi-channel power sourcing (1)
- multiresolution analysis (1)
- near infrared (1)
- near-infrared (1)
- next generation sequencing (1)
- nitrogen dioxide (1)
- non-woven fiber mats (1)
- operando Raman spectroscopies (1)
- optical coherence tomography (1)
- optical safeguard sensor (1)
- optical triangulation (1)
- opto-electronic protective device (1)
- ozonation (1)
- physical activity (1)
- physiological monitoring (1)
- presentation attack detection (1)
- presentation attack detection (PAD) (1)
- primäre Explosivstoffe (1)
- prioritizable ranking (1)
- sensor resilience (1)
- sexual assault (1)
- short tandem repeat (1)
- short tandem repeat (STR) (1)
- signal processing algorithm (1)
- skin detection (1)
- slope based signature (1)
- sperm cell (1)
- strain (1)
- stress (1)
- supramolecular liquid crystals (1)
- thermosensing (1)
- time series analysis (1)
- transmission phase gratings (1)
- triacetone triperoxides (1)
- tunable pitch (1)
- tungsten oxides (1)
- two-photon polymerization (1)
- ultrapure water (1)
- ultrasonic sensor (1)
- volatile organic compound (VOC) sensing (1)
- wearable technology (1)
- whole genome amplification (WGA) (1)
Entering the work envelope of an industrial robot can lead to severe injury from collisions with moving parts of the system. Conventional safety mechanisms therefore mostly restrict access to the robot using physical barriers such as walls and fences or non-contact protective devices including light curtains and laser scanners. As none of these mechanisms applies to human-robot-collaboration (HRC), a concept in which human and machine complement one another by working hand in hand, there is a rising need for safe and reliable detection of human body parts amidst background clutter. For this application camera-based systems are typically well suited. Still, safety concerns remain, owing to possible detection failures caused by environmental occlusion, extraneous light or other adverse imaging conditions. While ultrasonic proximity sensing can provide physical diversity to the system, it does not yet allow to reliably distinguish relevant objects from background objects.This work investigates a new approach to detecting relevant objects and human body parts based on acoustic holography. The approach is experimentally validated using a low-cost application-specific ultrasonic sensor system created from micro-electromechanical systems (MEMS). The presented results show that this system far outperforms conventional proximity sensors in terms of lateral imaging resolution and thus allows for more intelligent muting processes without compromising the safety of people working close to the robot. Based upon this work, a next step could be the development of a multimodal sensor systems to safeguard workers who collaborate with robots using the described ultrasonic sensor system.
The application of Raman and infrared (IR) microspectroscopy is leading to hyperspectral data containing complementary information concerning the molecular composition of a sample. The classification of hyperspectral data from the individual spectroscopic approaches is already state-of-the-art in several fields of research. However, more complex structured samples and difficult measuring conditions might affect the accuracy of classification results negatively and could make a successful classification of the sample components challenging. This contribution presents a comprehensive comparison in supervised pixel classification of hyperspectral microscopic images, proving that a combined approach of Raman and IR microspectroscopy has a high potential to improve classification rates by a meaningful extension of the feature space. It shows that the complementary information in spatially co-registered hyperspectral images of polymer samples can be accessed using different feature extraction methods and, once fused on the feature-level, is in general more accurately classifiable in a pattern recognition task than the corresponding classification results for data derived from the individual spectroscopic approaches.
The choice of suitable semiconducting metal oxide (MOX) gas sensors for the detection of a specific gas or gas mixture is time-consuming since the sensor’s sensitivity needs to be characterized at multiple temperatures to find its optimal operating conditions. To obtain reliable measurement results, it is very important that the power for the sensor’s integrated heater is stable, regulated and error-free (or error-tolerant). Especially the error-free requirement can be only be achieved if the power supply implements failure-avoiding and failure-detection methods. The biggest challenge is deriving multiple different voltages from a common supply in an efficient way while keeping the system as small and lightweight as possible. This work presents a reliable, compact, embedded system that addresses the power supply requirements for fully automated simultaneous sensor characterization for up to 16 sensors at multiple temperatures. The system implements efficient (avg. 83.3% efficiency) voltage conversion with low ripple output (<32 mV) and supports static or temperature-cycled heating modes. Voltage and current of each channel are constantly monitored and regulated to guarantee reliable operation. To evaluate the proposed design, 16 sensors were screened. The results are shown in the experimental part of this work.
Surface-enhanced Raman spectroscopy (SERS) with subsequent chemometric evaluation was performed for the rapid and non-destructive differentiation of seven important meat-associated microorganisms, namely Brochothrix thermosphacta DSM 20171, Pseudomonas fluorescens DSM 4358, Salmonella enterica subsp. enterica sv. Enteritidis DSM 14221, Listeria monocytogenes DSM 19094, Micrococcus luteus DSM 20030, Escherichia coli HB101 and Bacillus thuringiensis sv. israelensis DSM 5724. A simple method for collecting spectra from commercial paper-based SERS substrates without any laborious pre-treatments was used. In order to prepare the spectroscopic data for classification at genera level with a subsequent chemometric evaluation consisting of principal component analysis and discriminant analysis, a pre-processing method with spike correction and sum normalisation was performed. Because of the spike correction rather than exclusion, and therefore the use of a balanced data set, the multivariate analysis of the data is significantly resilient and meaningful. The analysis showed that the differentiation of meat-associated microorganisms and thereby the detection of important meat-related pathogenic bacteria was successful on genera level and a cross-validation as well as a classification of ungrouped data showed promising results, with 99.5 % and 97.5 %, respectively.
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100Ω to 5 GΩ (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.
Kollaborative Industrieroboter werden für produzierende Unternehmen immer kosteneffizienter. Während diese Systeme für den menschlichen Mitarbeiter eine große Hilfe sein können, stellen sie gleichzeitig ein ernstes Gesundheitsrisiko dar, wenn die zwingend notwendigen Sicherheitsmaßnahmen nur unzureichend umgesetzt werden. Herkömmliche Sicherheitseinrichtungen wie Zäune oder Lichtvorhänge bieten einen guten Schutz, aber solch statische Schutzvorrichtungen sind in neuen, hochdynamischen Arbeitsszenarien problematisch.
Im Forschungsprojekt BeyondSPAI wurde ein Funktionsmuster eines Multisensorsystems zur Absicherung solcher dynamischer Arbeitsszenarien entworfen, implementiert und im Feld getestet. Kern des Systems ist eine robuste optische Materialklassifikation, die mit Hilfe eines intelligenten InGaAs-Kamerasystems Haut von anderen typischen Werkstückoberflächen (z.B. Holz, Metalle od. Kunststoffe) unterscheiden kann. Diese einzigartige Eigenschaft wird genutzt, um menschliche Mitarbeiter zuverlässig zu erkennen, so dass ein konventioneller Roboter in Folge als personenbewusster Cobot arbeiten kann.
Das System ist modular und kann leicht mit weiteren Sensoren verschiedenster Art erweitert werden. Es kann an verschiedene Marken von Industrierobotern angepasst werden und lässt sich schnell an bestehenden Robotersystemen integrieren. Die vier vom System bereitgestellten Sicherheitsausgänge können dazu verwendet werden - abhängig von der durchdrungenen Überwachungszone - entweder eine Warnung auszugeben, die Bewegung des Roboters auf eine sichere Geschwindigkeit zu verlangsamen, oder den Roboter sicher anzuhalten. Sobald alle Zonen wieder als „eindeutig frei von Personen“ identifiziert sind, kann der Roboter wieder beschleunigen, seine ursprüngliche Bewegung wiederaufnehmen und die Arbeit fortsetzen.
Explorative experiments were done to figure out differences in the emission of volatile organic compounds (VOCs) of not infested trees and trees infested by Anoplophora glabripennis (Asian longhorn beetle, ALB), a quarantine pest. Therefore, VOCs from some native insect species, Anoplophora glabripennis infested Acer, stressed Acer, healthy Acer, Populus and Salix were obtained by enrichment on adsorbents. Qualitative analysis was done by thermal desorption gas chromatography coupled with a mass selective detector (TD-GC/MS). Altogether 169 substances were identified. 11 substances occur from ALB infested or mechanically damaged trees i.e. stressed trees, but not from healthy trees. (+)-Cyclosativene, (+)-α-longipinene, copaene and caryophyllene are detectable only from ALB-infested Acer not from mechanically damaged or healthy Acer. However, these substances are also emitted by healthy Salix. 2,4-Dimethyl-1-heptene is among all tree samples exclusively present in the ambience of ALB-infested trees. It´s rarely detectable from native insect species’ samples.
Optical gas sensors based on chiral-nematic liquid crystals (N* LCs) forming one-dimensional photonic crystals do not require electrical energy and have a considerable potential to supplement established types of sensors. A chiral-nematic phase with tunable selective reflection is induced in a nematic host LC by adding reactive chiral dopants. The selective chemical reaction between dopant and analyte is capable to vary the pitch length (the lattice constant) of the soft, self-assembled, one-dimensional photonic crystal. The progress of the ongoing chemical reaction can be observed even by naked eye because the color of the samples varies. In this work, we encapsulate the responsive N* LC in microscale polyvinylpyrrolidone (PVP) fibers via coaxial electrospinning. The sensor is, thus, given a solid form and has an improved stability against nonavoidable environmental influences. The reaction behavior of encapsulated and nonencapsulated N* LC toward a gaseous analyte is compared, systematically. Making use of the encapsulation is an important step to improve the applicability.
Because the robust and rapid determination of spoilage microorganisms is becoming increasingly important in industry, the use of IR microspectroscopy, and the establishment of robust and versatile chemometric models for data processing and classification, is gaining importance. To further improve the chemometric models, bacterial stress responses were induced, to study the effect on the IR spectra and to improve the chemometric model. Thus, in this work, nine important food-relevant microorganisms were subjected to eight stress conditions, besides the regular culturing as a reference. Spectral changes compared to normal growth conditions without stressors were found in the spectral regions of 900–1500 cm−1 and 1500–1700 cm−1. These differences might stem from changes in the protein secondary structure, exopolymer production, and concentration of nucleic acids, lipids, and polysaccharides. As a result, a model for the discrimination of the studied microorganisms at the genus, species and strain level was established, with an accuracy of 96.6%. This was achieved despite the inclusion of various stress conditions and times after incubation of the bacteria. In addition, a model was developed for each individual microorganism, to separate each stress condition or regular treatment with 100% accuracy.
Intimate swabs taken for examination in sexual assault cases typically yield mixtures of sperm and epithelial cell types. While powerful, differential extraction protocols to overcome such cell type mixtures by separate lysis of epithelial cells and spermatozoa can still prove ineffective, in particular if only few sperm cells are present or if swabs contain sperm from more than one individual leading to complex low level DNA mixtures. A means to avoid such mixtures consists in the analysis of single micromanipulated sperm cells. However, the quantity of DNA from single sperm cells is not sufficient for conventional STR analysis. Here, we describe a simple method for micromanipulating individual sperm cells from intimate swabs and show that whole genome amplification can generate sufficient amounts of DNA from single cells for subsequent DNA profiling. We recovered over 80% of alleles of haploid autosomal STR profiles from the majority of individual sperm cells. Furthermore, we demonstrate that in mixtures of sperm from two contributors, Y-STR and X-STR profiles of individual sperm cells can be used to sort the haploid autosomal profiles to develop the diploid consensus STR profiles of the individual donors. Finally, by analysing single sperm cells from mock sexual assault swabs with one or two sperm donors, we showed that our protocols enabled the identification of the unknown male contributors.
A series of reactive binaphthyl‐diimine‐based dopants is prepared and investigated with respect to their potential for the chiral induction of structural coloration in nematic liquid crystal mixture E7 and the selective photonic sensing of nitrogen dioxide (NO2). Studies of the helical twisting power (HTP) in 4‐cyano‐4′‐pentylbiphenyl (5CB) reveal HTP values as high as 375 µm‐1 and the tremendous impact of structural compatibility and changes of the dihedral binaphthyl angle on the efficiency of the chiral transfer. Detailed investigation of the sensing capabilities of the systems reveals an extraordinarily high selectivity for NO2 and a response to concentrations as low as 100 ppm. The systems show a direct response to the analyte gas leading to a concentration‐dependent shift of the reflectance wavelength of up to several hundred nanometers. Incorporation of copper ions remarkably improves the sensor's properties in terms of sensitivity and selectivity, enabling the tailored tweaking of the system's properties.