Refine
H-BRS Bibliography
- yes (93) (remove)
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (93) (remove)
Document Type
- Article (43)
- Conference Object (34)
- Report (5)
- Doctoral Thesis (3)
- Patent (3)
- Contribution to a Periodical (2)
- Part of a Book (1)
- Conference Proceedings (1)
- Research Data (1)
Year of publication
Keywords
- Chemometrics (4)
- DNA typing (3)
- Raman spectroscopy (3)
- Classification (2)
- Cooperative Awareness Message (2)
- Discriminant analysis (2)
- Hyperspectral image (2)
- Intelligent Transport System (2)
- Principal Components Analysis (2)
- Privacy (2)
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100Ω to 5 GΩ (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.
Surface-enhanced Raman spectroscopy (SERS) with subsequent chemometric evaluation was performed for the rapid and non-destructive differentiation of seven important meat-associated microorganisms, namely Brochothrix thermosphacta DSM 20171, Pseudomonas fluorescens DSM 4358, Salmonella enterica subsp. enterica sv. Enteritidis DSM 14221, Listeria monocytogenes DSM 19094, Micrococcus luteus DSM 20030, Escherichia coli HB101 and Bacillus thuringiensis sv. israelensis DSM 5724. A simple method for collecting spectra from commercial paper-based SERS substrates without any laborious pre-treatments was used. In order to prepare the spectroscopic data for classification at genera level with a subsequent chemometric evaluation consisting of principal component analysis and discriminant analysis, a pre-processing method with spike correction and sum normalisation was performed. Because of the spike correction rather than exclusion, and therefore the use of a balanced data set, the multivariate analysis of the data is significantly resilient and meaningful. The analysis showed that the differentiation of meat-associated microorganisms and thereby the detection of important meat-related pathogenic bacteria was successful on genera level and a cross-validation as well as a classification of ungrouped data showed promising results, with 99.5 % and 97.5 %, respectively.
Optical gas sensors based on chiral-nematic liquid crystals (N* LCs) forming one-dimensional photonic crystals do not require electrical energy and have a considerable potential to supplement established types of sensors. A chiral-nematic phase with tunable selective reflection is induced in a nematic host LC by adding reactive chiral dopants. The selective chemical reaction between dopant and analyte is capable to vary the pitch length (the lattice constant) of the soft, self-assembled, one-dimensional photonic crystal. The progress of the ongoing chemical reaction can be observed even by naked eye because the color of the samples varies. In this work, we encapsulate the responsive N* LC in microscale polyvinylpyrrolidone (PVP) fibers via coaxial electrospinning. The sensor is, thus, given a solid form and has an improved stability against nonavoidable environmental influences. The reaction behavior of encapsulated and nonencapsulated N* LC toward a gaseous analyte is compared, systematically. Making use of the encapsulation is an important step to improve the applicability.
Explorative experiments were done to figure out differences in the emission of volatile organic compounds (VOCs) of not infested trees and trees infested by Anoplophora glabripennis (Asian longhorn beetle, ALB), a quarantine pest. Therefore, VOCs from some native insect species, Anoplophora glabripennis infested Acer, stressed Acer, healthy Acer, Populus and Salix were obtained by enrichment on adsorbents. Qualitative analysis was done by thermal desorption gas chromatography coupled with a mass selective detector (TD-GC/MS). Altogether 169 substances were identified. 11 substances occur from ALB infested or mechanically damaged trees i.e. stressed trees, but not from healthy trees. (+)-Cyclosativene, (+)-α-longipinene, copaene and caryophyllene are detectable only from ALB-infested Acer not from mechanically damaged or healthy Acer. However, these substances are also emitted by healthy Salix. 2,4-Dimethyl-1-heptene is among all tree samples exclusively present in the ambience of ALB-infested trees. It´s rarely detectable from native insect species’ samples.
The choice of suitable semiconducting metal oxide (MOX) gas sensors for the detection of a specific gas or gas mixture is time-consuming since the sensor’s sensitivity needs to be characterized at multiple temperatures to find its optimal operating conditions. To obtain reliable measurement results, it is very important that the power for the sensor’s integrated heater is stable, regulated and error-free (or error-tolerant). Especially the error-free requirement can be only be achieved if the power supply implements failure-avoiding and failure-detection methods. The biggest challenge is deriving multiple different voltages from a common supply in an efficient way while keeping the system as small and lightweight as possible. This work presents a reliable, compact, embedded system that addresses the power supply requirements for fully automated simultaneous sensor characterization for up to 16 sensors at multiple temperatures. The system implements efficient (avg. 83.3% efficiency) voltage conversion with low ripple output (<32 mV) and supports static or temperature-cycled heating modes. Voltage and current of each channel are constantly monitored and regulated to guarantee reliable operation. To evaluate the proposed design, 16 sensors were screened. The results are shown in the experimental part of this work.
The application of Raman and infrared (IR) microspectroscopy is leading to hyperspectral data containing complementary information concerning the molecular composition of a sample. The classification of hyperspectral data from the individual spectroscopic approaches is already state-of-the-art in several fields of research. However, more complex structured samples and difficult measuring conditions might affect the accuracy of classification results negatively and could make a successful classification of the sample components challenging. This contribution presents a comprehensive comparison in supervised pixel classification of hyperspectral microscopic images, proving that a combined approach of Raman and IR microspectroscopy has a high potential to improve classification rates by a meaningful extension of the feature space. It shows that the complementary information in spatially co-registered hyperspectral images of polymer samples can be accessed using different feature extraction methods and, once fused on the feature-level, is in general more accurately classifiable in a pattern recognition task than the corresponding classification results for data derived from the individual spectroscopic approaches.
In the context of the Franco-German research project Re(h)strain, this work focuses on a global system analysis integrating both safety and security analysis of international and/or urban railway stations. The Re(h)strain project focuses on terrorist attacks on high speed train systems and investigates prevention and mitigation measures to reduce the overall vulnerability and strengthen the system resilience. One main criterion regarding public transport issues is the number of passengers. For example, the railway station of Paris “Gare du Nord” deals with a bigger number of passengers than the biggest airport in the world (SNCF open Data 2014), the Atlanta airport, but in terms of passengers, it is only around the 23rd rank railway station in the world. Due to the enormous mass of people, this leads to the system approach of breaking out the station into several classes of zones, e.g. entrance, main hall, quays, trains, etc. All classes are analysed considering state-of-the-art parameters, like targets attractiveness, feasibility of attack, possible damage, possible mitigation and defences. Then, safety incidence of security defence is discussed in order to refine security requirement with regard to the considered zone. Finally, global requirements of security defence correlated to the corresponding class of zones are proposed.
Entering the work envelope of an industrial robot can lead to severe injury from collisions with moving parts of the system. Conventional safety mechanisms therefore mostly restrict access to the robot using physical barriers such as walls and fences or non-contact protective devices including light curtains and laser scanners. As none of these mechanisms applies to human-robot-collaboration (HRC), a concept in which human and machine complement one another by working hand in hand, there is a rising need for safe and reliable detection of human body parts amidst background clutter. For this application camera-based systems are typically well suited. Still, safety concerns remain, owing to possible detection failures caused by environmental occlusion, extraneous light or other adverse imaging conditions. While ultrasonic proximity sensing can provide physical diversity to the system, it does not yet allow to reliably distinguish relevant objects from background objects.This work investigates a new approach to detecting relevant objects and human body parts based on acoustic holography. The approach is experimentally validated using a low-cost application-specific ultrasonic sensor system created from micro-electromechanical systems (MEMS). The presented results show that this system far outperforms conventional proximity sensors in terms of lateral imaging resolution and thus allows for more intelligent muting processes without compromising the safety of people working close to the robot. Based upon this work, a next step could be the development of a multimodal sensor systems to safeguard workers who collaborate with robots using the described ultrasonic sensor system.
Die Detektion von Explosivstoffen stellt ein zentrales Feld der zivilen Sicherheitsforschung dar. Eine besondere Herausforderung liegt hierbei in dem Nachweis verpackter Substanzen, wie es bei Unkonventionellen Spreng- und Brandvorrichtung (USBV) häufig der Fall ist. Derzeit eingesetzte Verfahren arbeiten meist mit bildgebenden Techniken, durch die sich ein Anfangsverdacht ergibt. Der tatsächliche chemische Inhalt der USBV lässt sich jedoch nicht exakt ermitteln. Eine genaue Beurteilung der Gefährdung durch solche Substanzen ist allerdings von großer Bedeutung, insbesondere wenn die Entschärfung des Objekts in bewohntem Gebiet stattfinden muss. In der vorliegenden Arbeit wird ein Verfahren vorgestellt, das sich als Verifikationsverfahren bei bestehendem Anfangsverdacht gezielt einsetzen lässt. Hierzu wird mittels Laserbohrtechnik zunächst die äußere Hülle des zu untersuchenden Gegenstandes durchdrungen. Anschließend finden eine lasergestützte Probenahme des Inhalts sowie die Detektion unter Verwendung geeigneter Analysemöglichkeiten statt. Der Bohr- und Probenahmefortschritt wird über verschiedene spektroskopische und sensorische Verfahren begleitend überwacht. Zukünftig soll das System abstandsfähig auf Entschärfungsrobotern eingesetzt werden.
The detection of human skin in images is a very desirable feature for applications such as biometric face recognition, which is becoming more frequently used for, e.g., automated border or access control. However, distinguishing real skin from other materials based on imagery captured in the visual spectrum alone and in spite of varying skin types and lighting conditions can be dicult and unreliable. Therefore, spoofing attacks with facial disguises or masks are still a serious problem for state of the art face recognition algorithms. This dissertation presents a novel approach for reliable skin detection based on spectral remission properties in the short-wave infrared (SWIR) spectrum and proposes a cross-modal method that enhances existing solutions for face verification to ensure the authenticity of a face even in the presence of partial disguises or masks. Furthermore, it presents a reference design and the necessary building blocks for an active multispectral camera system that implements this approach, as well as an in-depth evaluation. The system acquires four-band multispectral images within T = 50ms. Using a machine-learning-based classifier, it achieves unprecedented skin detection accuracy, even in the presence of skin-like materials used for spoofing attacks. Paired with a commercial face recognition software, the system successfully rejected all evaluated attempts to counterfeit a foreign face.