Simultaneous multifrequency radio observations of the Galactic Centre magnetar SGR J1745-2900
(2015)
We present the performance of the upGREAT heterodyne array receivers on the SOFIA telescope after several years of operations. This instrument is a multi-pixel high resolution (R≳107) spectrometer for the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA). The receivers use 7-pixel subarrays configured in a hexagonal layout around a central pixel. The low frequency array receiver (LFA) has 2×7 pixels (dual polarization), and presently covers the 1.83–2.07THz frequency range, which allows to observe the [CII] and [OI] lines at 158μm and 145μm wavelengths. The high frequency array (HFA) covers the [OI] line at 63μm and is equipped with one polarization at the moment (7 pixels, which can be upgraded in the near future with a second polarization array). The 4.7THz array has successfully flown using two separate quantum-cascade laser local oscillators from two different groups. NASA completed the development, integration and testing of a dual-channel closed-cycle cryocooler system, with two independently operable He compressors, aboard SOFIA in early 2017 and since then, both arrays can be operated in parallel using a frequency separating dichroic mirror. This configuration is now the prime GREAT configuration and has been added to SOFIA’s instrument suite since observing cycle 6.
We present a new multi-pixel high resolution (R ≳ 107) spectrometer for the Stratospheric Observatory for Far-Infrared Astronomy (SOFIA). The receiver uses 2 × 7-pixel subarrays in orthogonal polarization, each in an hexagonal array around a central pixel. We present the first results for this new instrument after commissioning campaigns in May and December 2015 and after science observations performed in May 2016. The receiver is designed to ultimately cover the full 1.8−2.5 THz frequency range but in its first implementation, the observing range was limited to observations of the [CII] line at 1.9 THz in 2015 and extended to 1.83−2.07 THz in 2016. The instrument sensitivities are state-of-the-art and the first scientific observations performed shortly after the commissioning confirm that the time efficiency for large scale imaging is improved by more than an order of magnitude as compared to single pixel receivers. An example of large scale mapping around the Horsehead Nebula is presented here illustrating this improvement. The array has been added to SOFIA’s instrument suite already for ongoing observing cycle 4.
Using the Atacama Pathfinder Experiment (APEX) telescope, we have detected the rotational ground-state transitions of ortho-ammonia and ortho-water toward the redshift 0.89 absorbing galaxy in the PKS 1830-211 gravitational lens system. We discuss our observations in the context of recent space-borne data obtained for these lines with the SWAS and Odin satellites toward Galactic sources. We find commonalities, but also significant differences between the interstellar media in a galaxy at intermediate redshift and in the Milky Way. Future high-quality observations of the ground-state ammonia transition in PKS 1830-211, together with inversion line data, will lead to strong constraints on the variation in the proton to electron mass ratio over the past 7.2 Gyr.
Context.We present the technology and first scientific results of a new generation of very flexible and sensitive spectrometers, well-suited for the needs of spectral-line radio and (sub)millimeter astronomy: Fast Fourier Transform Spectrometers (FFTS), which are in operation at the Atacama Pathfinder EXperiment (APEX) telescope.
Aims. The FFTS for APEX is a novel high-resolution 2 x 1 GHz bandwidth digital spectrometer backend. Due to its high frequency resolution, and the demonstrated capability of operating at high altitude, the FFTS became the facility spectrometer for spectral line observations at APEX.
Methods. The FFTS is based on one of the currently most powerful digitizer/analyzer boards available from Acqiris, Switzerland. The board incorporates two 1 Gsamples/s analog-to-digital converters (ADCs) with 8-bit resolution which feed an on-board complex field programmable gate array (FPGA) chip. The enormous processing power by today's FPGAs allow for a complete real-time FFT signal processing pipeline to decompose a 1 GHz band into 16 384 spectral channels in just one chip.
Results. Since May 2005 an MPIfR FFTS has been extensively used in all regular spectroscopic science observations. The performance at APEX was demonstrated to be very reliable and as good as measured in the first laboratory tests which finally led to the request to provide a second, facility type FFTS for APEX. The unit was delivered and commissioned in March this year.
Conclusions. Using a commercially available digitizer board, it was possible to develop a complete FFTS in only a few months. Successful observations at APEX demonstrate that this new generation of FPGA-based spectrometers easily matching and superseding the performance of older technology spectrometers and can built up much more easily. Furthermore, the by now available class of new high-speed ADCs and the continuous increase of FPGA processing power makes it very likely that FFTS can be pushed to broader bandwidth and even more spectral channels in the near future.