Refine
H-BRS Bibliography
- yes (50)
Departments, institutes and facilities
Document Type
- Article (29)
- Conference Object (16)
- Report (3)
- Part of a Book (1)
- Patent (1)
Year of publication
Keywords
- Chemometrics (3)
- Raman spectroscopy (3)
- Classification (2)
- Discriminant analysis (2)
- Hyperspectral image (2)
- Principal Components Analysis (2)
- Raman microscopy (2)
- Raman-microspectroscopy (2)
- SERS (2)
- TNT (2)
Timely recognition of threats can be significantly supported by security assistance systems that work continuously in time and call the security personnel in case of anomalous events in the surveillance area. We describe the concept and the realization of an indoor security assistance system for real-time decision support. The system consists of a computer vision module and a person classification module. The computer vision module provides a video event analysis of the entrance region in front of the demonstrator. After entering the control corridor, the persons are tracked, classified, and potential threats are localized inside the demonstrator. Data for the person classification are provided by chemical sensors detecting hazardous materials. Due to their limited spatio-temporal resolution, a single chemical sensor cannot localize this material and associate it with a person. We compensate this deficiency by fusing the output of multiple, distributed chemical sensors with kinematical data from laser-range scanners. Considering both the computer vision formation and the results of the person classification affords the localization of threats and a timely reaction of the security personnel.
Bisher ist nicht bekannt, in welchem Ausmaß Fremd- oder Störgerüche dazu geeignet sind, die allgemeine Leistungsfähigkeit eines Sprengstoffspürhundes einzuschränken oder sogar die Detektion eines Sprengkörpers zu verhindern. Ziel ist es zu untersuchen, inwieweit sich durch den gezielten Einsatz von Störsubstanzen die Sprengstoffdetektionsfähigkeit von Spürhunden beeinflussen lässt. Mit Detektionsfähigkeit ist hier sowohl die Wahrscheinlichkeit einer richtigen Detektion von Sprengstoffen in Gegenwart von starken Fremdgerüchen, als auch die ebenfalls zu erwartende Verringerung der Einsatzdauer (vorzeitige Erschöpfung) gemeint.
Hydrophilic surface-enhanced Raman spectroscopy (SERS) substrates were prepared by a combination of TiO2-coatings of aluminium plates through a direct titanium tetraisopropoxide (TTIP) coating and drop coated by synthesised gold nanoparticles (AuNPs). Differences between the wettability of the untreated substrates, the slowly dried Ti(OH)4 substrates and calcinated as well as plasma treated TiO2 substrates were analysed by water contact angle (WCA) measurements. The hydrophilic behaviour of the developed substrates helped to improve the distribution of the AuNPs, which reflects in overall higher lateral SERS enhancement. Surface enhancement of the substrates was tested with target molecule rhodamine 6G (R6G) and a fibre-coupled 638 nm Raman spectrometer. Additionally, the morphology of the substrates was characterised using scanning electron microscopy (SEM) and Raman microscopy. The studies showed a reduced influence of the coffee ring effect on the particle distribution, resulting in a more broadly distributed edge region, which increased the spatial reproducibility of the measured SERS signal in the surface-enhanced Raman mapping measurements on mm scale.
Surface-enhanced Raman spectroscopy (SERS) with subsequent chemometric evaluation was performed for the rapid and non-destructive differentiation of seven important meat-associated microorganisms, namely Brochothrix thermosphacta DSM 20171, Pseudomonas fluorescens DSM 4358, Salmonella enterica subsp. enterica sv. Enteritidis DSM 14221, Listeria monocytogenes DSM 19094, Micrococcus luteus DSM 20030, Escherichia coli HB101 and Bacillus thuringiensis sv. israelensis DSM 5724. A simple method for collecting spectra from commercial paper-based SERS substrates without any laborious pre-treatments was used. In order to prepare the spectroscopic data for classification at genera level with a subsequent chemometric evaluation consisting of principal component analysis and discriminant analysis, a pre-processing method with spike correction and sum normalisation was performed. Because of the spike correction rather than exclusion, and therefore the use of a balanced data set, the multivariate analysis of the data is significantly resilient and meaningful. The analysis showed that the differentiation of meat-associated microorganisms and thereby the detection of important meat-related pathogenic bacteria was successful on genera level and a cross-validation as well as a classification of ungrouped data showed promising results, with 99.5 % and 97.5 %, respectively.
P30 - Das Elektrospinnen von halbleitenden Zinndioxidfasern für die Detektion von Wasserstoff
(2022)
Das Ziel dieser Arbeit ist die Entwicklung von dünnen keramischen Fasern als halbleitendes Sensormaterial zum Nachweis von Wasserstoff, möglichst bei Zimmertemperatur. Die elektrische Leitfähigkeit halbleitender Metalloxide ändert sich durch die Einwirkung von oxidierenden und reduzierenden Gasen auf die Oberfläche des Metalloxids. Dieser Effekt kann zur Messung der Gaskonzentration genutzt werden. Die Reaktion von Zinn(IV)-oxid mit Wasserstoff basiert auf der Reduktion des Zinn(IV)-oxids zum Zinn, wobei die Elektronen des Zinn(IV)-oxids im metallischen Zinn verbleiben und dort im nicht gebundenen Zustand zu einer Leitfähigkeitserhöhung beitragen. Die Reaktion des Wasserstoffes kann sowohl mit den Sauerstoffatomen des Oxids als auch mit adsorbierten Sauerstoffatomen an der Oxidoberfläche stattfinden.[ 6] Da die Reaktionen an der Oberfläche des Oxids stattfinden, sollten Sensoren mit einer großen Oberfläche im Vergleich zu metalloxidischen Bulkmaterialien eine höhere Empfindlichkeit aufweisen. [3] Die Verwendung von Fasern anstelle von Dünn- oder Dickschichten führt dabei zu einer besseren Sensitivität gegenüber Gasen.
In the context of the Franco-German research project Re(h)strain, this work focuses on a global system analysis integrating both safety and security analysis of international and/or urban railway stations. The Re(h)strain project focuses on terrorist attacks on high speed train systems and investigates prevention and mitigation measures to reduce the overall vulnerability and strengthen the system resilience. One main criterion regarding public transport issues is the number of passengers. For example, the railway station of Paris “Gare du Nord” deals with a bigger number of passengers than the biggest airport in the world (SNCF open Data 2014), the Atlanta airport, but in terms of passengers, it is only around the 23rd rank railway station in the world. Due to the enormous mass of people, this leads to the system approach of breaking out the station into several classes of zones, e.g. entrance, main hall, quays, trains, etc. All classes are analysed considering state-of-the-art parameters, like targets attractiveness, feasibility of attack, possible damage, possible mitigation and defences. Then, safety incidence of security defence is discussed in order to refine security requirement with regard to the considered zone. Finally, global requirements of security defence correlated to the corresponding class of zones are proposed.
The following work presents algorithms for semi-automatic validation, feature extraction and ranking of time series measurements acquired from MOX gas sensors. Semi-automatic measurement validation is accomplished by extending established curve similarity algorithms with a slope-based signature calculation. Furthermore, a feature-based ranking metric is introduced. It allows for individual prioritization of each feature and can be used to find the best performing sensors regarding multiple research questions. Finally, the functionality of the algorithms, as well as the developed software suite, are demonstrated with an exemplary scenario, illustrating how to find the most power-efficient MOX gas sensor in a data set collected during an extensive screening consisting of 16,320 measurements, all taken with different sensors at various temperatures and analytes.
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100Ω to 5 GΩ (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.
The choice of suitable semiconducting metal oxide (MOX) gas sensors for the detection of a specific gas or gas mixture is time-consuming since the sensor’s sensitivity needs to be characterized at multiple temperatures to find its optimal operating conditions. To obtain reliable measurement results, it is very important that the power for the sensor’s integrated heater is stable, regulated and error-free (or error-tolerant). Especially the error-free requirement can be only be achieved if the power supply implements failure-avoiding and failure-detection methods. The biggest challenge is deriving multiple different voltages from a common supply in an efficient way while keeping the system as small and lightweight as possible. This work presents a reliable, compact, embedded system that addresses the power supply requirements for fully automated simultaneous sensor characterization for up to 16 sensors at multiple temperatures. The system implements efficient (avg. 83.3% efficiency) voltage conversion with low ripple output (<32 mV) and supports static or temperature-cycled heating modes. Voltage and current of each channel are constantly monitored and regulated to guarantee reliable operation. To evaluate the proposed design, 16 sensors were screened. The results are shown in the experimental part of this work.
Sicherheit im Fährverkehr
(2012)
Ausführungsbeispiele schaffen eine Vorrichtung zur Desinfektion oder Sanitisierung zumindest eines Gegenstands. Die Vorrichtung umfasst einen Ozongenerator, der ausgebildet ist, um Ozon zu erzeugen und in einem Volumen freizusetzen. Ferner umfasst die Vorrichtung einen Ozonsensor, der ausgebildet ist, um eine Ozonkonzentration in dem Volumen zu messen. Ferner umfasst die Vorrichtung eine Steuereinrichtung, die konfiguriert ist, um den Ozongenerator anzusteuern Ozon zu erzeugen, so dass eine gemessene Ozonkonzentration für einen vorgegebenen Zeitraum bei einer vorgegebenen Ozonkonzentration oder innerhalb eines vorgegebenen Ozonkonzentrationsbereichs liegt, um in dem Volumen befindliche Gegenstände zu desinfizieren oder sanitisieren.
Because the robust and rapid determination of spoilage microorganisms is becoming increasingly important in industry, the use of IR microspectroscopy, and the establishment of robust and versatile chemometric models for data processing and classification, is gaining importance. To further improve the chemometric models, bacterial stress responses were induced, to study the effect on the IR spectra and to improve the chemometric model. Thus, in this work, nine important food-relevant microorganisms were subjected to eight stress conditions, besides the regular culturing as a reference. Spectral changes compared to normal growth conditions without stressors were found in the spectral regions of 900–1500 cm−1 and 1500–1700 cm−1. These differences might stem from changes in the protein secondary structure, exopolymer production, and concentration of nucleic acids, lipids, and polysaccharides. As a result, a model for the discrimination of the studied microorganisms at the genus, species and strain level was established, with an accuracy of 96.6%. This was achieved despite the inclusion of various stress conditions and times after incubation of the bacteria. In addition, a model was developed for each individual microorganism, to separate each stress condition or regular treatment with 100% accuracy.
Discrimination of Stressed and Non-Stressed Food-Related Bacteria Using Raman-Microspectroscopy
(2022)
As the identification of microorganisms becomes more significant in industry, so does the utilization of microspectroscopy and the development of effective chemometric models for data analysis and classification. Since only microorganisms cultivated under laboratory conditions can be identified, but they are exposed to a variety of stress factors, such as temperature differences, there is a demand for a method that can take these stress factors and the associated reactions of the bacteria into account. Therefore, bacterial stress reactions to lifetime conditions (regular treatment, 25 °C, HCl, 2-propanol, NaOH) and sampling conditions (cold sampling, desiccation, heat drying) were induced to explore the effects on Raman spectra in order to improve the chemometric models. As a result, in this study nine food-relevant bacteria were exposed to seven stress conditions in addition to routine cultivation as a control. Spectral alterations in lipids, polysaccharides, nucleic acids, and proteins were observed when compared to normal growth circumstances without stresses. Regardless of the involvement of several stress factors and storage times, a model for differentiating the analyzed microorganisms from genus down to strain level was developed. Classification of the independent training dataset at genus and species level for Escherichia coli and at strain level for the other food relevant microorganisms showed a classification rate of 97.6%.