The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100Ω to 5 GΩ (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.
In the presented project, new approaches for the prevention of hand movements leading to hazards and for non-contact detection of fingers are intended to permit comprehensive and economical protection on circular saws. The basic principles may also be applied to other machines with manual loading and/or unloading. Two new detection principles are explained. The first is the distinction between skin and wood or other material by spectral analysis in the near infrared region. Using LED and photodiodes it is possible to detect fingers and hands reliable. With a kind of light curtain the intrusion into the dangerous zone near the blade can be prevented. The second principle is video image processing to detect persons, arms and fingers. In the first stage of development the detection of upper limb extremities within a defined hazard area by means of a computer based video image analysis is investigated.
Vorrichtung zur Authentifikation einer Person anhand mindestens eines biometrischen Parameters
(2008)
Die Vorrichtung zur Authentifikation einer Person anhand mindestens eines biometrischen Parameters, insbesondere anhand eines Fingerabdrucks, ist versehen mit einem Biometrie-Detektor (20) zur Detektion eines biometrischen Parameters, einem Haut-Detektor (24) zur berührungslosen Erkennung lebender menschlicher Haut innerhalb eines Erfassungsbereichs. Der Haut-Detektor (24) weist mindestens eine Gruppe aus mindestens einer Strahlungseinheit (26, 28) und mindestens einer Empfangseinheit (30) auf. Die mindestens eine Strahlungseinheit (26, 28) gibt in Richtung auf den Erfassungsbereich Strahlung bei mindestens zwei unterschiedlichen Wellenlängen im Wellenlängenbereich zwischen 400 nm und 1500 nm ab, wobei mindestens eine der Wellenlängen (26, 28) im Wellenlängenbereich von 900 nm bis 1500 nm liegt und die mindestens eine Empfangseinheit (30) aus dem Erfassungsbereich reflektierte Strahlung empfängt. Ferner ist die Vorrichtung versehen mit einer mit dem Biometer-Detektor (20) und dem Haut-Detektor (24) verbundenen Signalauswerteeinheit (22) zur Auswertung der Intensität der von der Empfangseinheit (30) empfangenen reflektierten Strahlungen der Strahlungseinheit (26, 28). In der Signalauswerteeinheit (22) ist anhand der Intensitäten der von der Empfangseinheit (30) empfangenen reflektierten Strahlungen der Strahlungseinheit (26, 28) bei den zwei unterschiedlichen Wellenlängen ermittelbar, ob der Haut-Detektor lebende menschliche Haut erkennt.