Refine
H-BRS Bibliography
- yes (20)
Departments, institutes and facilities
- Fachbereich Informatik (19)
- Institute of Visual Computing (IVC) (17)
- Fachbereich Wirtschaftswissenschaften (3)
- Institut für Sicherheitsforschung (ISF) (2)
- Fachbereich Angewandte Naturwissenschaften (1)
- Fachbereich Ingenieurwissenschaften und Kommunikation (1)
- Institut für funktionale Gen-Analytik (IFGA) (1)
- Präsidium (1)
Document Type
- Article (20) (remove)
Year of publication
Keywords
- AR (1)
- Centrifugation (1)
- Chemical imaging (1)
- Discrete cosine transform (1)
- Displacement (1)
- EEG (1)
- ERP (1)
- Event detection (1)
- Exercise (1)
- Expert system (1)
Zentrale Archivierung und verteilte Kommunikation digitaler Bilddaten in der Pneumokoniosevorsorge
(2010)
Pneumokoniose-Vorsorgeuntersuchungen erfordern die Befundung einer Röntgenthoraxaufnahme nach ILO-Staublungenklassifikation. Inzwischen werden die benötigten Aufnahmen bereits in großem Umfang digital angefertigt und kommuniziert. Hierdurch entstehen neue Anforderungen an verwendete Technik und Workflow-Mechanismen, um einen effizienten Ablauf von Untersuchung, Befundung und Dokumentation zu gewährleisten.
Neutral buoyancy has been used as an analog for microgravity from the earliest days of human spaceflight. Compared to other options on Earth, neutral buoyancy is relatively inexpensive and presents little danger to astronauts while simulating some aspects of microgravity. Neutral buoyancy removes somatosensory cues to the direction of gravity but leaves vestibular cues intact. Removal of both somatosensory and direction of gravity cues while floating in microgravity or using virtual reality to establish conflicts between them has been shown to affect the perception of distance traveled in response to visual motion (vection) and the perception of distance. Does removal of somatosensory cues alone by neutral buoyancy similarly impact these perceptions? During neutral buoyancy we found no significant difference in either perceived distance traveled nor perceived size relative to Earth-normal conditions. This contrasts with differences in linear vection reported between short- and long-duration microgravity and Earth-normal conditions. These results indicate that neutral buoyancy is not an effective analog for microgravity for these perceptual effects.
Maintaining orientation in an environment with non-Earth gravity (1 g) is critical for an astronaut's operational performance. Such environments present a number of complexities for balance and motion. For example, when an astronaut tilts due to ascending or descending an inclined plane on the moon, the gravity vector will be tilted correctly, but the magnitude will be different from on earth. If this results in a mis-perceived tilt, then that may lead to postural and perceptual errors, such as mis-perceiving the orientation of oneself or the ground plane and corresponding errors in task judgment.
The relative contributions of radial and laminar optic flow to the perception of linear self-motion
(2012)
When illusory self-motion is induced in a stationary observer by optic flow, the perceived distance traveled is generally overestimated relative to the distance of a remembered target (Redlick, Harris, & Jenkin, 2001): subjects feel they have gone further than the simulated distance and indicate that they have arrived at a target's previously seen location too early. In this article we assess how the radial and laminar components of translational optic flow contribute to the perceived distance traveled. Subjects monocularly viewed a target presented in a virtual hallway wallpapered with stripes that periodically changed color to prevent tracking. The target was then extinguished and the visible area of the hallway shrunk to an oval region 40° (h) × 24° (v). Subjects either continued to look centrally or shifted their gaze eccentrically, thus varying the relative amounts of radial and laminar flow visible. They were then presented with visual motion compatible with moving down the hallway toward the target and pressed a button when they perceived that they had reached the target's remembered position. Data were modeled by the output of a leaky spatial integrator (Lappe, Jenkin, & Harris, 2007). The sensory gain varied systematically with viewing eccentricity while the leak constant was independent of viewing eccentricity. Results were modeled as the linear sum of separate mechanisms sensitive to radial and laminar optic flow. Results are compatible with independent channels for processing the radial and laminar flow components of optic flow that add linearly to produce large but predictable errors in perceived distance traveled.
The application of Raman and infrared (IR) microspectroscopy is leading to hyperspectral data containing complementary information concerning the molecular composition of a sample. The classification of hyperspectral data from the individual spectroscopic approaches is already state-of-the-art in several fields of research. However, more complex structured samples and difficult measuring conditions might affect the accuracy of classification results negatively and could make a successful classification of the sample components challenging. This contribution presents a comprehensive comparison in supervised pixel classification of hyperspectral microscopic images, proving that a combined approach of Raman and IR microspectroscopy has a high potential to improve classification rates by a meaningful extension of the feature space. It shows that the complementary information in spatially co-registered hyperspectral images of polymer samples can be accessed using different feature extraction methods and, once fused on the feature-level, is in general more accurately classifiable in a pattern recognition task than the corresponding classification results for data derived from the individual spectroscopic approaches.
The perceptual upright results from the multisensory integration of the directions indicated by vision and gravity as well as a prior assumption that upright is towards the head. The direction of gravity is signalled by multiple cues, the predominant of which are the otoliths of the vestibular system and somatosensory information from contact with the support surface. Here, we used neutral buoyancy to remove somatosensory information while retaining vestibular cues, thus "splitting the gravity vector" leaving only the vestibular component. In this way, neutral buoyancy can be used as a microgravity analogue. We assessed spatial orientation using the oriented character recognition test (OChaRT, which yields the perceptual upright, PU) under both neutrally buoyant and terrestrial conditions. The effect of visual cues to upright (the visual effect) was reduced under neutral buoyancy compared to on land but the influence of gravity was unaffected. We found no significant change in the relative weighting of vision, gravity, or body cues, in contrast to results found both in long-duration microgravity and during head-down bed rest. These results indicate a relatively minor role for somatosensation in determining the perceptual upright in the presence of vestibular cues. Short-duration neutral buoyancy is a weak analogue for microgravity exposure in terms of its perceptual consequences compared to long-duration head-down bed rest.