Refine
H-BRS Bibliography
- yes (20)
Departments, institutes and facilities
- Fachbereich Informatik (19)
- Institute of Visual Computing (IVC) (17)
- Fachbereich Wirtschaftswissenschaften (3)
- Institut für Sicherheitsforschung (ISF) (2)
- Fachbereich Angewandte Naturwissenschaften (1)
- Fachbereich Ingenieurwissenschaften und Kommunikation (1)
- Institut für funktionale Gen-Analytik (IFGA) (1)
- Präsidium (1)
Document Type
- Article (20) (remove)
Year of publication
Keywords
- AR (1)
- Centrifugation (1)
- Chemical imaging (1)
- Discrete cosine transform (1)
- Displacement (1)
- EEG (1)
- ERP (1)
- Event detection (1)
- Exercise (1)
- Expert system (1)
Zentrale Archivierung und verteilte Kommunikation digitaler Bilddaten in der Pneumokoniosevorsorge
(2010)
Pneumokoniose-Vorsorgeuntersuchungen erfordern die Befundung einer Röntgenthoraxaufnahme nach ILO-Staublungenklassifikation. Inzwischen werden die benötigten Aufnahmen bereits in großem Umfang digital angefertigt und kommuniziert. Hierdurch entstehen neue Anforderungen an verwendete Technik und Workflow-Mechanismen, um einen effizienten Ablauf von Untersuchung, Befundung und Dokumentation zu gewährleisten.
Die Fachhochschulen haben sich als Hochschulen für angewandte Wissenschaften seit ihrer Gründung Anfang der 70er Jahre deutlich gewandelt. Das Fächerportfolio vieler Fachhochschulen ist inzwischen mit jenem der Universitäten vergleichbar. In einigen Fächern bilden die Fachhochschulen sogar den überwiegenden Anteil von Absolventen aus. Die anwendungsorientierte Spitzenforschung gehört zum Selbstverständnis vieler Fachhochschulen. Vor diesem Hintergrund ist es unverständlich und für die wirtschaftliche Zukunftsfähigkeit schädlich, dass Fachhochschulen immer noch deutliche Wettbewerbsnachteile in der Weiterqualifizierung des wissenschaftlichen Nachwuchses haben. Dies gilt umso mehr, wenn mit Fachhochschulen vergleichbaren privaten Hochschulen das Promotionsrecht zugestanden wird.
The relative contributions of radial and laminar optic flow to the perception of linear self-motion
(2012)
When illusory self-motion is induced in a stationary observer by optic flow, the perceived distance traveled is generally overestimated relative to the distance of a remembered target (Redlick, Harris, & Jenkin, 2001): subjects feel they have gone further than the simulated distance and indicate that they have arrived at a target's previously seen location too early. In this article we assess how the radial and laminar components of translational optic flow contribute to the perceived distance traveled. Subjects monocularly viewed a target presented in a virtual hallway wallpapered with stripes that periodically changed color to prevent tracking. The target was then extinguished and the visible area of the hallway shrunk to an oval region 40° (h) × 24° (v). Subjects either continued to look centrally or shifted their gaze eccentrically, thus varying the relative amounts of radial and laminar flow visible. They were then presented with visual motion compatible with moving down the hallway toward the target and pressed a button when they perceived that they had reached the target's remembered position. Data were modeled by the output of a leaky spatial integrator (Lappe, Jenkin, & Harris, 2007). The sensory gain varied systematically with viewing eccentricity while the leak constant was independent of viewing eccentricity. Results were modeled as the linear sum of separate mechanisms sensitive to radial and laminar optic flow. Results are compatible with independent channels for processing the radial and laminar flow components of optic flow that add linearly to produce large but predictable errors in perceived distance traveled.
Using virtual environment systems for road safety education requires a realistic simulation of road traffic. Current traffic simulations are either too restricted in their complexity of agent behavior or focus on aspects not important in virtual environments. More importantly, none of them are concerned with modeling misbehavior of traffic participants which is part of every-day traffic and should therefore not be neglected in this context. We present a concept for a traffic simulation that addresses the need for more realistic agent behavior with regard to road safety education. The two major components of this concept are a simulation of persistent agents which minimizes computational overhead and a model of cognitive processes of human drivers combined with psychological personality profiles to allow for individual behavior and misbehavior.
Might the gravity levels found on other planets and on the moon be sufficient to provide an adequate perception of upright for astronauts? Can the amount of gravity required be predicted from the physiological threshold for linear acceleration? The perception of upright is determined not only by gravity but also visual information when available and assumptions about the orientation of the body. Here, we used a human centrifuge to simulate gravity levels from zero to earth gravity along the long-axis of the body and measured observers' perception of upright using the Oriented Character Recognition Test (OCHART) with and without visual cues arranged to indicate a direction of gravity that differed from the body's long axis. This procedure allowed us to assess the relative contribution of the added gravity in determining the perceptual upright. Control experiments off the centrifuge allowed us to measure the relative contributions of normal gravity, vision, and body orientation for each participant. We found that the influence of 1 g in determining the perceptual upright did not depend on whether the acceleration was created by lying on the centrifuge or by normal gravity. The 50% threshold for centrifuge-simulated gravity's ability to influence the perceptual upright was at around 0.15 g, close to the level of moon gravity but much higher than the threshold for detecting linear acceleration along the long axis of the body. This observation may partially explain the instability of moonwalkers but is good news for future missions to Mars.
Virtual reality environments are increasingly being used to encourage individuals to exercise more regularly, including as part of treatment in those with mental health or neurological disorders. The success of virtual environments likely depends on whether a sense of presence can be established, where participants become fully immersed in the virtual environment. Exposure to virtual environments is associated with physiological responses, including cortical activation changes. Whether the addition of a real exercise within a virtual environment alters sense of presence perception, or the accompanying physiological changes, is not known. In a randomized and controlled study design, trials of moderate-intensity exercise (i.e. self-paced cycling) and no-exercise (i.e. automatic propulsion) were performed within three levels of virtual environment exposure. Each trial was 5-min in duration and was followed by post-trial assessments of heart rate, perceived sense of presence, EEG, and mental state. Changes in psychological strain and physical state were generally mirrored by neural activation patterns. Furthermore these change indicated that exercise augments the demands of virtual environment exposures and this likely contributed to an enhanced sense of presence.
Maintaining orientation in an environment with non-Earth gravity (1 g) is critical for an astronaut's operational performance. Such environments present a number of complexities for balance and motion. For example, when an astronaut tilts due to ascending or descending an inclined plane on the moon, the gravity vector will be tilted correctly, but the magnitude will be different from on earth. If this results in a mis-perceived tilt, then that may lead to postural and perceptual errors, such as mis-perceiving the orientation of oneself or the ground plane and corresponding errors in task judgment.
Females are influenced more than males by visual cues during many spatial orientation tasks; but females rely more heavily on gravitational cues during visual-vestibular conflict. Are there gender biases in the relative contributions of vision, gravity and the internal representation of the body to the perception of upright? And might any such biases be affected by low gravity? 16 participants (8 female) viewed a highly polarized visual scene tilted ±112° while lying supine on the European Space Agency's short-arm human centrifuge. The centrifuge was rotated to simulate 24 logarithmically spaced g-levels along the long axis of the body (0.04-0.5g at ear-level). The perception of upright was measured using the Oriented Character Recognition Test (OCHART). OCHART uses the ambiguous symbol "p" shown in different orientations. Participants decided whether it was a "p" or a "d" from which the perceptual upright (PU) can be calculated for each visual/gravity combination. The relative contribution of vision, gravity and the internal representation of the body were then calculated. Experiments were repeated while upright. The relative contribution of vision on the PU was less in females compared to males (t=-18.48, p≤0.01). Females placed more emphasis on the gravity cue instead (f:28.4%, m:24.9%) while body weightings were constant (f:63.0%, m:63.2%). When upright (1g) in this and other studies (e.g., Barnett-Cowan et al. 2010, EJN, 31,1899) females placed more emphasis on vision in this task than males. The reduction in weight allocated by females to vision when in simulated low-gravity conditions compared to when upright under normal gravity may be related to similar female behaviour in response to other instances of visual-vestibular conflict. Why this is the case and at which point the perceptual change happens requires further research.
The application of Raman and infrared (IR) microspectroscopy is leading to hyperspectral data containing complementary information concerning the molecular composition of a sample. The classification of hyperspectral data from the individual spectroscopic approaches is already state-of-the-art in several fields of research. However, more complex structured samples and difficult measuring conditions might affect the accuracy of classification results negatively and could make a successful classification of the sample components challenging. This contribution presents a comprehensive comparison in supervised pixel classification of hyperspectral microscopic images, proving that a combined approach of Raman and IR microspectroscopy has a high potential to improve classification rates by a meaningful extension of the feature space. It shows that the complementary information in spatially co-registered hyperspectral images of polymer samples can be accessed using different feature extraction methods and, once fused on the feature-level, is in general more accurately classifiable in a pattern recognition task than the corresponding classification results for data derived from the individual spectroscopic approaches.
BACKGROUND: Humans demonstrate many physiological changes in microgravity for which long-duration head down bed rest (HDBR) is a reliable analog. However, information on how HDBR affects sensory processing is lacking.
OBJECTIVE: We previously showed [25] that microgravity alters the weighting applied to visual cues in determining the perceptual upright (PU), an effect that lasts long after return. Does long-duration HDBR have comparable effects?
METHODS: We assessed static spatial orientation using the luminous line test (subjective visual vertical, SVV) and the oriented character recognition test (PU) before, during and after 21 days of 6° HDBR in 10 participants. Methods were essentially identical as previously used in orbit [25].
RESULTS: Overall, HDBR had no effect on the reliance on visual relative to body cues in determining the PU. However, when considering the three critical time points (pre-bed rest, end of bed rest, and 14 days post-bed rest) there was a significant decrease in reliance on visual relative to body cues, as found in microgravity. The ratio had an average time constant of 7.28 days and returned to pre-bed-rest levels within 14 days. The SVV was unaffected.
CONCLUSIONS: We conclude that bed rest can be a useful analog for the study of the perception of static self-orientation during long-term exposure to microgravity. More detailed work on the precise time course of our effects is needed in both bed rest and microgravity conditions.
The perceptual upright results from the multisensory integration of the directions indicated by vision and gravity as well as a prior assumption that upright is towards the head. The direction of gravity is signalled by multiple cues, the predominant of which are the otoliths of the vestibular system and somatosensory information from contact with the support surface. Here, we used neutral buoyancy to remove somatosensory information while retaining vestibular cues, thus "splitting the gravity vector" leaving only the vestibular component. In this way, neutral buoyancy can be used as a microgravity analogue. We assessed spatial orientation using the oriented character recognition test (OChaRT, which yields the perceptual upright, PU) under both neutrally buoyant and terrestrial conditions. The effect of visual cues to upright (the visual effect) was reduced under neutral buoyancy compared to on land but the influence of gravity was unaffected. We found no significant change in the relative weighting of vision, gravity, or body cues, in contrast to results found both in long-duration microgravity and during head-down bed rest. These results indicate a relatively minor role for somatosensation in determining the perceptual upright in the presence of vestibular cues. Short-duration neutral buoyancy is a weak analogue for microgravity exposure in terms of its perceptual consequences compared to long-duration head-down bed rest.
Neutral buoyancy has been used as an analog for microgravity from the earliest days of human spaceflight. Compared to other options on Earth, neutral buoyancy is relatively inexpensive and presents little danger to astronauts while simulating some aspects of microgravity. Neutral buoyancy removes somatosensory cues to the direction of gravity but leaves vestibular cues intact. Removal of both somatosensory and direction of gravity cues while floating in microgravity or using virtual reality to establish conflicts between them has been shown to affect the perception of distance traveled in response to visual motion (vection) and the perception of distance. Does removal of somatosensory cues alone by neutral buoyancy similarly impact these perceptions? During neutral buoyancy we found no significant difference in either perceived distance traveled nor perceived size relative to Earth-normal conditions. This contrasts with differences in linear vection reported between short- and long-duration microgravity and Earth-normal conditions. These results indicate that neutral buoyancy is not an effective analog for microgravity for these perceptual effects.