Prof. Dr.-Ing. Rainer Herpers
Refine
Departments, institutes and facilities
- Fachbereich Informatik (134)
- Institute of Visual Computing (IVC) (114)
- Institut für funktionale Gen-Analytik (IFGA) (9)
- Institut für Sicherheitsforschung (ISF) (7)
- Fachbereich Angewandte Naturwissenschaften (3)
- Fachbereich Ingenieurwissenschaften und Kommunikation (3)
- Fachbereich Wirtschaftswissenschaften (3)
- Präsidium (1)
Document Type
- Conference Object (95)
- Article (21)
- Report (13)
- Part of a Book (7)
- Conference Proceedings (4)
- Part of Periodical (1)
Year of publication
Keywords
- Virtual Reality (4)
- FPGA (3)
- Hyperspectral image (3)
- Image Processing (3)
- Perceptual Upright (3)
- virtual reality (3)
- Forschungsbericht (2)
- Gravitation (2)
- Intelligent virtual agents (2)
- Perception (2)
In interactive graphics it is often necessary to introduce large changes in the image in response to updated information about the state of the system. Updating the local state immediately would lead to a sudden transient change in the image, which could be perceptually disruptive. However, introducing the correction gradually using smoothing operations increases latency and degrades precision. It would be beneficial to be able to introduce graphic updates immediately if they were not perceptible. In the paper the use of saccade-contingent updates is exploited to hide graphic updates during the period of visual suppression that accompanies a rapid, or saccadic, eye movement. Sensitivity to many visual stimuli is known to be reduced during a change in fixation compared to when the eye is still. For example, motion of a small object is harder to detect during a rapid eye movement (saccade) than during a fixation. To evaluate if these findings generalize to large scene changes in a virtual environment, gaze behavior in a 180 degree hemispherical display was recorded and analyzed. This data was used to develop a saccade detection algorithm adapted to virtual environments. The detectability of trans-saccadic scene changes was evaluated using images of high resolution real world scenes. The images were translated by 0.4, 0.8 or 1.2 degrees of visual angle during horizontal saccades. The scene updates were rarely noticeable for saccades with a duration greater than 58 ms. The detection rate for the smallest translation was just 6.25%. Qualitatively, even when trans-saccadic scene changes were detectible, they were much less disturbing than equivalent changes in the absence of a saccade.
Motion parameters estimation of moving objects and ego motion applying an active camera system
(2004)
The objective of the presented approach is to develop a 3D-reconstruction method for micro organisms from sequences of microscopic images by varying the level-of-focus. The approach is limited to translucent silicatebased marine and freshwater organisms (e.g. radiolarians). The proposed 3D-reconstruction method exploits the connectivity of similarly oriented and spatially adjacent edge elements in consecutive image layers. This yields a 3D-mesh representing the global shape of the objects together with details of the inner structure. Possible applications can be found in comparative morphology or hydrobiology, where e.g. deficiencies in growth and structure during incubation in toxic water or gravity effects on metabolism have to be determined.
In this contribution a machine vision inspection system is presented which is designed as a length measuring sensor. It is developed to be applied to a range of heat shrink tubes, varying in length, diameter and color. The challenges of this task were the precision and accuracy demands as well as the real-time applicability of the entire approach since it should be realized in regular industrial line production. In production, heat shrink tubes are cut to specific sizes from a continuous tube. A multi-measurement strategy has been developed, which measures each individual tube segment several times with sub pixel accuracy while being in the visual field. The developed approach allows for a contact-free and fully automatic control of 100% of produced heat shrink tubes according to the given requirements with a measuring precision of 0.1mm. Depending on the color, length and diameter of the tubes considered, a true positive rate of 99.99% to 100% has been reached at a true negative rate of > 99.7.