Dr. Peter Kusch
Refine
H-BRS Bibliography
- yes (59)
Departments, institutes and facilities
Document Type
- Article (33)
- Part of a Book (17)
- Book (monograph, edited volume) (4)
- Contribution to a Periodical (4)
- Conference Object (1)
Year of publication
Keywords
- GC/MS (11)
- Analytical pyrolysis (4)
- Corrosion inhibitors (4)
- Failure analysis (3)
- Polymers (3)
- Primary long-chain alkyl amines (3)
- Pyrolysis (3)
- Automotive industry (2)
- Chromatography (2)
- GC-FID/NPD (2)
Analysis of Synthetic Polymers and Copolymers by Pyrolysis- Gas Chromatography/Mass Spectrometry
(2005)
Structural analysis and the study of degradation properties are important in order to understand and improve performance characteristics of synthetic polymers and copolymers in many industrial applications. Polymers/copolymers are inherently difficult to analyze because of their high molecular weight and lack of volatility. Traditionally, various analytical techniques are used to characterize polymers/copolymers including physical testing (rheological testing), thermogravimetric analysis (TGA), electron microscopy, Fourier transform infrared (FTIR) spectroscopy, size-exclusion chromatography (SEC)/gel permeation chromatography (GPC), and mass spectrometry (MS). Often, time consuming sample preparation, including hydrolysis, dissolution, or derivatization is needed before analysis.
Analytical pyrolysis
(2019)
Analytical pyrolysis deals with the structural identification and quantitation of pyrolysis products with the ultimate aim of establishing the identity of the original material and the mechanisms of its thermal decomposition. The pyrolytic process is carried out in a pyrolyzer interfaced with analytical instrumentation such as gas chromatography (GC), mass spectrometry (MS), gas chromatography coupled with mass spectrometry (GC/MS), or with Fourier-transform infrared spectroscopy (GC/FTIR). By measurement and identification of pyrolysis products, the molecular composition of the original sample can often be reconstructed.This book is the outcome of contributions by experts in the field of pyrolysis and includes applications of the analytical pyrolysis-GC/MS to characterize the structure of synthetic organic polymers and lignocellulosic materials as well as cellulosic pulps and isolated lignins, solid wood, waste particle board, and bio-oil. The thermal degradation of cellulose and biomass is examined by scanning electron micrography, FTIR spectroscopy, thermogravimetry (TG), differential thermal analysis, and TG/MS. The calorimetric determination of high heating values of different raw biomass, plastic waste, and biomass/plastic waste mixtures and their by-products resulting from pyrolysis is described.
Die Wiederverwertung von Kunststoffen (Kunststoffrecycling) kann in die werkstoffliche (materielle), die rohstoffliche (chemische) und die energetische Verwertung unterteilt werden. Beim werkstofflichen Kunststoffrecycling werden sortenreine Kunststoffreste gewaschen, gemahlen und von der Kunststoff verarbeitenden Industrie als Rohmaterial eingesetzt. Der chemische Aufbau des erhaltenen Werkstoffs (Re-Granulats) bleibt erhalten. Bei der rohstofflichen Verwertung werden Kunststoffreste zu Monomeren zurückgeführt. Die erhaltenen Monomere werden dann bei der Herstellung neuer Kunststoffe verwendet. Bei der energetischen Verwertung werden die Kunststoffreste der Zement- oder Stahlindustrie als Energieträger zugeführt.
This book chapter describes application examples of gas chromatography/mass spectrometry and pyrolysis – gas chromatography/mass spectrometry in failure analysis for the identification of chemical materials like mineral oils and nitrile rubber gaskets. Furthermore, failure cases demanding identification of polymers/copolymers in fouling on the compressor wall of a car air conditioner and identification of fouling on the surface of a bearing race from the automotive industry are demonstrated. The obtained analytical results were then used for troubleshooting and remedial action of the technological process.
The analytical pyrolysis technique hyphenated to gas chromatography–mass spectrometry (GC–MS) has extended the range of possible tools for the characterization of synthetic polymers and copolymers. Pyrolysis involves thermal fragmentation of the analytical sample at temperatures of 500–1400 °C. In the presence of an inert gas, reproducible decomposition products characteristic for the original polymer or copolymer sample are formed. The pyrolysis products are chromatographically separated using a fused-silica capillary column and are subsequently identified by interpretation of the obtained mass spectra or by using mass spectra libraries. The analytical technique eliminates the need for pretreatment by performing analyses directly on the solid or liquid polymer sample. In this article, application examples of analytical pyrolysis hyphenated to GC–MS for the identification of different polymeric materials in the plastic and automotive industry, dentistry, and occupational safety are demonstrated. For the first time, results of identification of commercial light-curing dental filling material and a car wrapping foil by pyrolysis–GC–MS are presented.
Analytical pyrolysis technique hyphenated to gas chromatography/mass spectrometry (Py-GC/MS) has extended the range of possible tools for characterization of synthetic polymers/copolymers. Pyrolysis involves thermal fragmentation of the analytical sample at elevated temperature between 500 and 1400 °C. In the presence of an inert gas, reproducible decomposition products characteristic for the original polymer/copolymer sample are formed. The pyrolysis products are chromatographically separated by using a fused silica capillary column and subsequently identified by interpretation of the obtained mass spectra or by using mass spectra libraries. The analytical technique eliminate the need for pre-treatment by performing analyses directly on the solid or liquid polymer sample.
In this paper, application examples of the analytical pyrolysis hyphenated to gas chromatography/mass spectrometry for the identification of different polymeric materials in the plastic and automotive industry, dentistry and occupational safety are demonstrated. For the first time results of identification of commercially light-curing dental filling material and a car wrapping foil by pyrolysis-GC/MS are presented.
The analytical pyrolysis technique hyphenated to gas chromatography–mass spectrometry (GC–MS) has extended the range of possible tools for the characterization of synthetic polymers and copolymers. Pyrolysis involves thermal fragmentation of the analytical sample at temperatures of 500–1400 °C. In the presence of an inert gas, reproducible decomposition products characteristic for the original polymer or copolymer sample are formed. The pyrolysis products are chromatographically separated using a fused-silica capillary column and are subsequently identified by interpretation of the obtained mass spectra or by using mass spectra libraries. The analytical technique eliminates the need for pretreatment by performing analyses directly on the solid or liquid polymer sample. In this article, application examples of analytical pyrolysis hyphenated to GC–MS for the identification of different polymeric materials in the plastic and automotive industry, dentistry, and occupational safety are demonstrated. For the first time, results of identification of commercial light-curing dental filling material and a car wrapping foil by pyrolysis–GC–MS are presented.
Gas chromatography with flame-ionization detection (FID) and gas chromatography-mass spectrometry (GC/MS) has been used for structure elucidation of long-chain primary n-alkyl amines after derivatization with trifluoroacetic anhydride (TFAA). Electron impact ionization- (EI) and positive chemical ionization- (PCI) mass spectra of trifluoroacetylated derivatives of the identified nalkyl amines are presented. The corrosion inhibiting n-alkyl amines were applied in the investigation of a new anticorrosive and antifouling formulation for water-steam circuit of energy systems in the power industry. The presented results are part of an EU-funded international collaboration with partners from research institutes and industry from Poland, Lithuania, Romania, France and Germany (EUREKA project BOILTREAT E!2426).
Miscanthus crops possess very attractive properties such as high photosynthesis yield and carbon fixation rate. Because of these properties, it is currently considered for use in second-generation biorefineries. Here we analyze the differences in chemical composition between M. x giganteus, a commonly studied Miscanthus genotype, and M. nagara, which is relatively understudied but has useful properties such as increased frost resistance and higher stem stability. Samples of M. x giganteus (Gig35) and M. nagara (NagG10) have been separated by plant portion (leaves and stems) in order to isolate the corresponding lignins. The organosolv process was used for biomass pulping (80% ethanol solution, 170 °C, 15 bar). Biomass composition and lignin structure analysis were performed using composition analysis, Fourier-transform infrared (FTIR), ultraviolet-visible (UV-Vis) and nuclear magnetic resonance (NMR) spectroscopy, thermogravimetric analysis (TGA), size exclusion chromatography (SEC) and pyrolysis gas-chromatography/mass spectrometry (Py-GC/MS) to determine the 3D structure of the isolated lignins, monolignol ratio and most abundant linkages depending on genotype and harvesting season. SEC data showed significant differences in the molecular weight and polydispersity indices for stem versus leaf-derived lignins. Py-GC/MS and hetero-nuclear single quantum correlation (HSQC) NMR revealed different monolignol compositions for the two genotypes (Gig35, NagG10). The monolignol ratio is slightly influenced by the time of harvest: stem-derived lignins of M. nagara showed increasing H and decreasing G unit content over the studied harvesting period (December–April).
Der zunehmende Einsatz der Polymerwerkstoffe in der Automobilindustrie erfordert empfindliche und zuverlässige Methoden zur Analyse der verwendeten Stoffe. Bei Schadenanalysen an Komponenten in Kraftfahrzeugen stehen oftmals nur wenige Informationen über das Bauteil selbst, wie die chemische Zusammensetzung, die Temperaturbeständigkeit, mögliche Kontaminierungs stoffe oder mechanische Eigenschaften zur Verfügung. Der Schadensbereich ist meistens be grenzt und nicht immer homogen. Zur Klärung des Schadens stehen häufig nur kleine Proben mengen zur Verfügung, die jedoch für die Erkennung der Schadensursache von großer Bedeutung sein können.