Refine
H-BRS Bibliography
- yes (43) (remove)
Departments, institutes and facilities
- Institut für Sicherheitsforschung (ISF) (43) (remove)
Document Type
- Article (43) (remove)
Year of publication
Keywords
- Chemometrics (3)
- DNA typing (3)
- Raman spectroscopy (3)
- Classification (2)
- Discriminant analysis (2)
- Principal Components Analysis (2)
- Raman-microspectroscopy (2)
- SERS (2)
- Short tandem repeat (STR) (2)
- automated sensor-screening (2)
- biometrics (2)
- classification (2)
- discriminant analysis (2)
- food-related bacteria (2)
- optical sensor (2)
- photonic sensing (2)
- semiconducting metal oxide gas sensor array (2)
- stress response (2)
- AOP (1)
- Agglomerative Hierarchical Cluster Analysis (1)
- Anoplophora glabripennis (1)
- AuNPs (1)
- Chemical imaging (1)
- Circular saws (1)
- Cooperative Awareness Message (1)
- DNA profile (1)
- Degraded DNA (1)
- E. coli (1)
- Fiber-optic probe (1)
- Forensic genetics (1)
- Forensic genomics (1)
- Fourier scatterometry (1)
- GC/MS (1)
- Hand injuries (1)
- Homemade explosives (1)
- IED (1)
- IR microspectroscopy (1)
- IR-microspectroscopy (1)
- Intelligent Transport System (1)
- Light curtain (1)
- Liquid crystal (1)
- MAP (1)
- MOX gas sensors (1)
- Meat-associated Microorganisms (1)
- Microorganisms (1)
- Mobile explosive identification (1)
- Multimodal hyperspectral data (1)
- Next Generation Sequencing (NGS) (1)
- O3/UV (1)
- OCT (1)
- PAD (1)
- PCR inhibitors (1)
- Pathogenic Bacteria (1)
- Pattern recognition (1)
- Poultry (1)
- Poultry meat (1)
- Poultry spoilage (1)
- Primary explosives (1)
- Principal component analysis (1)
- Privacy (1)
- Probabilistic methods (1)
- Propellants (1)
- Protective system (1)
- Ps. fluorescens (1)
- Pseudonym Concept (1)
- Raman Spectroscopy (1)
- Rapid method (1)
- Safety guard (1)
- Skin detection (1)
- Spectroscopy (1)
- Spoilage (1)
- Spoilage bacteria (1)
- Supervised classification (1)
- Support vector machines (1)
- TD-GC/MS (1)
- TNT (1)
- TOC (1)
- Telogen hair (1)
- TiO2-coatings (1)
- VOC (1)
- Vehicle-2-Vehicle Communication (1)
- Vehicular Ad hoc Networks (1)
- Vibrational microspectroscopy (1)
- Volatile organic compounds (1)
- Whole genome amplification (1)
- X-STR (1)
- Y-STR (1)
- analog/digital signal processing (1)
- authentication (1)
- automatic measurement validation (1)
- bacteria (1)
- bioinformatics (1)
- chemometrics (1)
- chemosensing (1)
- chiral-nematic (1)
- cholesteric liquid crystals (1)
- cholesteric phase (1)
- coaxial electrospinning (1)
- coffee ring effect (1)
- core-sheath fibers (1)
- degraded DNA (1)
- detection (1)
- displacement measurement (1)
- electrospinning (1)
- encapsulation (1)
- estimation (1)
- feature (1)
- fingerprint (1)
- food safety (1)
- forensic (1)
- forensic genetics (1)
- gas sensor (1)
- grating reconstruction (1)
- halogen bonding (1)
- helical twisting power (1)
- high degree of diagnostic coverage and reliability (1)
- high diagnostic coverage and reliability (1)
- high dynamic range resistance readout (1)
- high-throughput sequencing (1)
- hydrogen bonding (1)
- liquid crystal (1)
- low molecular weight (1)
- massive parallel sequencing (1)
- metal-oxide-semiconductor gas sensors (1)
- micromanipulation (1)
- multi-channel power sourcing (1)
- near infrared (1)
- next generation sequencing (1)
- nitrogen dioxide (1)
- non-woven fiber mats (1)
- operando Raman spectroscopies (1)
- optical coherence tomography (1)
- optical triangulation (1)
- opto-electronic protective device (1)
- ozonation (1)
- presentation attack detection (1)
- presentation attack detection (PAD) (1)
- prioritizable ranking (1)
- sensor resilience (1)
- sexual assault (1)
- short tandem repeat (1)
- short tandem repeat (STR) (1)
- signal processing algorithm (1)
- slope based signature (1)
- sperm cell (1)
- supramolecular liquid crystals (1)
- thermosensing (1)
- time series analysis (1)
- transmission phase gratings (1)
- triacetone triperoxides (1)
- tunable pitch (1)
- tungsten oxides (1)
- two-photon polymerization (1)
- ultrapure water (1)
- volatile organic compound (VOC) sensing (1)
- wearable technology (1)
- whole genome amplification (WGA) (1)
In this work, the surface reactions of the homemade explosive triacetone triperoxide on tungsten oxide (WO3) sensor surfaces are studied to obtain detailed information about the chemical reactions taking place. Semiconductor gas sensors based on WO3 nanopowders are therefore produced and characterized by scanning electron microscopy, X-ray diffraction, and Raman spectroscopy. To analyze the reaction mechanisms at the sensor surface, the sensor is monitored online under operation conditions using Raman spectroscopy, which allows to identify the temperature-dependent sensor reactions. By combining information from the Raman spectra with data on the changing resistivity of the underlying semiconductor, it is possible to establish a correlation between the adsorbed gas species and the physical properties of the WO3 layer. In the results, it is indicated that a Lewis acid–base reaction is the most likely mechanism for the increase in resistance observed at temperatures below 150 °C. In the results, at higher temperatures, the assumption of a radical mechanism that causes a decrease in resistance is supported.
A deployment of the Vehicle-2-Vehicle communication technology according to ETSI is in preparation in Europe. Currently, a policy for a necessary Public Key Infrastructure to enrol cryptographic keys and certificates for vehicles and infrastructure component is in discussion to enable an interoperable Vehicle-2-Vehicle communication. Vehicle-2-Vehicle communication means that vehicles periodically send Cooperative Awareness Messages. These messages contain the current geographic position, driving direction, speed, acceleration, and the current time of a vehicle. To protect privacy (location privacy, “speed privacy”) of vehicles and drivers ETSI provides a specific pseudonym concept. We show that the Vehicle-2-Vehicle communication can be misused by an attacker to plot a trace of sequent Cooperative Awareness Messages and to link this trace to a specific vehicle. Such a trace is non-disputable due to the cryptographic signing of the messages. So, the periodically sending of Cooperative Awareness Messages causes privacy problems even if the pseudonym concept is applied.
Intimate swabs taken for examination in sexual assault cases typically yield mixtures of sperm and epithelial cell types. While powerful, differential extraction protocols to overcome such cell type mixtures by separate lysis of epithelial cells and spermatozoa can still prove ineffective, in particular if only few sperm cells are present or if swabs contain sperm from more than one individual leading to complex low level DNA mixtures. A means to avoid such mixtures consists in the analysis of single micromanipulated sperm cells. However, the quantity of DNA from single sperm cells is not sufficient for conventional STR analysis. Here, we describe a simple method for micromanipulating individual sperm cells from intimate swabs and show that whole genome amplification can generate sufficient amounts of DNA from single cells for subsequent DNA profiling. We recovered over 80% of alleles of haploid autosomal STR profiles from the majority of individual sperm cells. Furthermore, we demonstrate that in mixtures of sperm from two contributors, Y-STR and X-STR profiles of individual sperm cells can be used to sort the haploid autosomal profiles to develop the diploid consensus STR profiles of the individual donors. Finally, by analysing single sperm cells from mock sexual assault swabs with one or two sperm donors, we showed that our protocols enabled the identification of the unknown male contributors.
Design of an Active Multispectral SWIR Camera System for Skin Detection and Face Verification
(2016)
Biometric face recognition is becoming more frequently used in different application scenarios. However, spoofing attacks with facial disguises are still a serious problem for state of the art face recognition algorithms. This work proposes an approach to face verification based on spectral signatures of material surfaces in the short wave infrared (SWIR) range. They allow distinguishing authentic human skin reliably from other materials, independent of the skin type. We present the design of an active SWIR imaging system that acquires four-band multispectral image stacks in real-time. The system uses pulsed small band illumination, which allows for fast image acquisition and high spectral resolution and renders it widely independent of ambient light. After extracting the spectral signatures from the acquired images, detected faces can be verified or rejected by classifying the material as "skin" or "no-skin". The approach is extensively evaluated with respect to both acquisition and classification performance. In addition, we present a database containing RGB and multispectral SWIR face images, as well as spectrometer measurements of a variety of subjects, which is used to evaluate our approach and will be made available to the research community by the time this work is published.
This paper presents recent research on an active multispectral scanning sensor capable of classifying an object's surface material in order to distinguish between different kinds of materials and human skin. The sensor itself has already been presented in previous work and can be used in conjunction with safeguarding equipment at manually-fed machines or robot workplaces, for example. This work shows how an extended sensor system with advanced material classifiers can be used to provide additional value by distinguishing different materials of work pieces in order to suggest different tools or parameters for the machine (e.g. the use of a different saw blade or rotation speed at table saws). Additionally, a first implementation and evaluation of an active multispectral camera system addressing new safety applications is described. Both approaches intend to increase the productivity and the user's acceptance of the sensor technology.
A series of reactive binaphthyl‐diimine‐based dopants is prepared and investigated with respect to their potential for the chiral induction of structural coloration in nematic liquid crystal mixture E7 and the selective photonic sensing of nitrogen dioxide (NO2). Studies of the helical twisting power (HTP) in 4‐cyano‐4′‐pentylbiphenyl (5CB) reveal HTP values as high as 375 µm‐1 and the tremendous impact of structural compatibility and changes of the dihedral binaphthyl angle on the efficiency of the chiral transfer. Detailed investigation of the sensing capabilities of the systems reveals an extraordinarily high selectivity for NO2 and a response to concentrations as low as 100 ppm. The systems show a direct response to the analyte gas leading to a concentration‐dependent shift of the reflectance wavelength of up to several hundred nanometers. Incorporation of copper ions remarkably improves the sensor's properties in terms of sensitivity and selectivity, enabling the tailored tweaking of the system's properties.
With the increasing demand for ultrapure water in the pharmaceutical and semiconductor industry, the need for precise measuring instruments for those applications is also growing. One critical parameter of water quality is the amount of total organic carbon (TOC). This work presents a system that uses the advantage of the increased oxidation power achieved with UV/O3 advanced oxidation process (AOP) for TOC measurement in combination with a significant miniaturization compared to the state of the art. The miniaturization is achieved by using polymer-electrolyte membrane (PEM) electrolysis cells for ozone generation in combination with UV-LEDs for irradiation of the measuring solution, as both components are significantly smaller than standard equipment. Conductivity measurement after oxidation is the measuring principle and measurements were carried out in the TOC range between 10 and 1000 ppb TOC. The suitability of the system for TOC measurement is demonstrated using the oxidation by ozonation combined with UV irradiation of defined concentrations of isopropyl alcohol (IPA).
Polymer fibers with liquid crystals (LCs) in the core have potential as autonomous sensors of airborne volatile organic compounds (VOCs), with a high surface-to-volume ratio enabling fast and sensitive response and an attractive non-woven textile form factor. We demonstrate their ability to continuously and quantitatively measure the concentration of toluene, cyclohexane, and isopropanol as representative VOCs, via the impact of each VOC on the LC birefringence. The response is fully reversible and repeatable over several cycles, the response time can be as low as seconds, and high sensitivity is achieved when the operating temperature is near the LC-isotropic transition temperature. We propose that a broad operating temperature range can be realized by combining fibers with different LC mixtures, yielding autonomous VOC sensors suitable for integration in apparel or in furniture that can compete with existing consumer-grade electronic VOC sensors in terms of sensitivity and response speed.
Due to their user-friendliness and reliability, biometric systems have taken a central role in everyday digital identity management for all kinds of private, financial and governmental applications with increasing security requirements. A central security aspect of unsupervised biometric authentication systems is the presentation attack detection (PAD) mechanism, which defines the robustness to fake or altered biometric features. Artifacts like photos, artificial fingers, face masks and fake iris contact lenses are a general security threat for all biometric modalities. The Biometric Evaluation Center of the Institute of Safety and Security Research (ISF) at the University of Applied Sciences Bonn-Rhein-Sieg has specialized in the development of a near-infrared (NIR)-based contact-less detection technology that can distinguish between human skin and most artifact materials. This technology is highly adaptable and has already been successfully integrated into fingerprint scanners, face recognition devices and hand vein scanners. In this work, we introduce a cutting-edge, miniaturized near-infrared presentation attack detection (NIR-PAD) device. It includes an innovative signal processing chain and an integrated distance measurement feature to boost both reliability and resilience. We detail the device’s modular configuration and conceptual decisions, highlighting its suitability as a versatile platform for sensor fusion and seamless integration into future biometric systems. This paper elucidates the technological foundations and conceptual framework of the NIR-PAD reference platform, alongside an exploration of its potential applications and prospective enhancements.
Optical gas sensors based on chiral-nematic liquid crystals (N* LCs) forming one-dimensional photonic crystals do not require electrical energy and have a considerable potential to supplement established types of sensors. A chiral-nematic phase with tunable selective reflection is induced in a nematic host LC by adding reactive chiral dopants. The selective chemical reaction between dopant and analyte is capable to vary the pitch length (the lattice constant) of the soft, self-assembled, one-dimensional photonic crystal. The progress of the ongoing chemical reaction can be observed even by naked eye because the color of the samples varies. In this work, we encapsulate the responsive N* LC in microscale polyvinylpyrrolidone (PVP) fibers via coaxial electrospinning. The sensor is, thus, given a solid form and has an improved stability against nonavoidable environmental influences. The reaction behavior of encapsulated and nonencapsulated N* LC toward a gaseous analyte is compared, systematically. Making use of the encapsulation is an important step to improve the applicability.
The application of Raman and infrared (IR) microspectroscopy is leading to hyperspectral data containing complementary information concerning the molecular composition of a sample. The classification of hyperspectral data from the individual spectroscopic approaches is already state-of-the-art in several fields of research. However, more complex structured samples and difficult measuring conditions might affect the accuracy of classification results negatively and could make a successful classification of the sample components challenging. This contribution presents a comprehensive comparison in supervised pixel classification of hyperspectral microscopic images, proving that a combined approach of Raman and IR microspectroscopy has a high potential to improve classification rates by a meaningful extension of the feature space. It shows that the complementary information in spatially co-registered hyperspectral images of polymer samples can be accessed using different feature extraction methods and, once fused on the feature-level, is in general more accurately classifiable in a pattern recognition task than the corresponding classification results for data derived from the individual spectroscopic approaches.
Forensic DNA profiles are established by multiplex PCR amplification of a set of highly variable short tandem repeat (STR) loci followed by capillary electrophoresis (CE) as a means to assign alleles to PCR products of differential length. Recently, CE analysis of STR amplicons has been supplemented by high-throughput next generation sequencing (NGS) techniques that are able to detect isoalleles bearing sequence polymorphisms and allow for an improved analysis of degraded DNA. Several such assays have been commercialised and validated for forensic applications. However, these systems are cost-effective only when applied to high numbers of samples. We report here an alternative, cost-efficient shallow-sequence output NGS assay called maSTR assay that, in conjunction with a dedicated bioinformatics pipeline called SNiPSTR, can be implemented with standard NGS instrumentation. In a back-to-back comparison with a CE-based, commercial forensic STR kit, we find that for samples with low DNA content, with mixed DNA from different individuals, or containing PCR inhibitors, the maSTR assay performs equally well, and with degraded DNA is superior to CE-based analysis. Thus, the maSTR assay is a simple, robust and cost-efficient NGS-based STR typing method applicable for human identification in forensic and biomedical contexts.
The human gut microbiota harbors untapped potential for biotechnological applications. Within the phylum of Bacteroidota, Phocaeicola vulgatus stands out as a promising candidate for sustainable production of key platform chemicals like succinate. However, genetic engineering of Phocaeicola sp. remains challenging due to its intricate molecular landscape. This study lays the groundwork for manipulating the central carbon pathways in Phocaeicola vulgatus, offering insights into overcoming genetic hurdles for increased succinate yields.
Hydrogen‐Bonded Cholesteric Liquid Crystals—A Modular Approach Toward Responsive Photonic Materials
(2022)
A supramolecular approach for photonic materials based on hydrogen-bonded cholesteric liquid crystals is presented. The modular toolbox of low-molecular-weight hydrogen-bond donors and acceptors provides a simple route toward liquid crystalline materials with tailor-made thermal and photonic properties. Initial studies reveal broad application potential of the liquid crystalline thin films for chemo- and thermosensing. The chemosensing performance is based on the interruption of the intermolecular forces between the donor and acceptor moieties by interference with halogen-bond donors. Future studies will expand the scope of analytes and sensing in aqueous media. In addition, the implementation of the reported materials in additive manufacturing and printed photonic devices is planned.
Explorative experiments were done to figure out differences in the emission of volatile organic compounds (VOCs) of not infested trees and trees infested by Anoplophora glabripennis (Asian longhorn beetle, ALB), a quarantine pest. Therefore, VOCs from some native insect species, Anoplophora glabripennis infested Acer, stressed Acer, healthy Acer, Populus and Salix were obtained by enrichment on adsorbents. Qualitative analysis was done by thermal desorption gas chromatography coupled with a mass selective detector (TD-GC/MS). Altogether 169 substances were identified. 11 substances occur from ALB infested or mechanically damaged trees i.e. stressed trees, but not from healthy trees. (+)-Cyclosativene, (+)-α-longipinene, copaene and caryophyllene are detectable only from ALB-infested Acer not from mechanically damaged or healthy Acer. However, these substances are also emitted by healthy Salix. 2,4-Dimethyl-1-heptene is among all tree samples exclusively present in the ambience of ALB-infested trees. It´s rarely detectable from native insect species’ samples.
Because the robust and rapid determination of spoilage microorganisms is becoming increasingly important in industry, the use of IR microspectroscopy, and the establishment of robust and versatile chemometric models for data processing and classification, is gaining importance. To further improve the chemometric models, bacterial stress responses were induced, to study the effect on the IR spectra and to improve the chemometric model. Thus, in this work, nine important food-relevant microorganisms were subjected to eight stress conditions, besides the regular culturing as a reference. Spectral changes compared to normal growth conditions without stressors were found in the spectral regions of 900–1500 cm−1 and 1500–1700 cm−1. These differences might stem from changes in the protein secondary structure, exopolymer production, and concentration of nucleic acids, lipids, and polysaccharides. As a result, a model for the discrimination of the studied microorganisms at the genus, species and strain level was established, with an accuracy of 96.6%. This was achieved despite the inclusion of various stress conditions and times after incubation of the bacteria. In addition, a model was developed for each individual microorganism, to separate each stress condition or regular treatment with 100% accuracy.
Discrimination of Stressed and Non-Stressed Food-Related Bacteria Using Raman-Microspectroscopy
(2022)
As the identification of microorganisms becomes more significant in industry, so does the utilization of microspectroscopy and the development of effective chemometric models for data analysis and classification. Since only microorganisms cultivated under laboratory conditions can be identified, but they are exposed to a variety of stress factors, such as temperature differences, there is a demand for a method that can take these stress factors and the associated reactions of the bacteria into account. Therefore, bacterial stress reactions to lifetime conditions (regular treatment, 25 °C, HCl, 2-propanol, NaOH) and sampling conditions (cold sampling, desiccation, heat drying) were induced to explore the effects on Raman spectra in order to improve the chemometric models. As a result, in this study nine food-relevant bacteria were exposed to seven stress conditions in addition to routine cultivation as a control. Spectral alterations in lipids, polysaccharides, nucleic acids, and proteins were observed when compared to normal growth circumstances without stresses. Regardless of the involvement of several stress factors and storage times, a model for differentiating the analyzed microorganisms from genus down to strain level was developed. Classification of the independent training dataset at genus and species level for Escherichia coli and at strain level for the other food relevant microorganisms showed a classification rate of 97.6%.