Hydrophilic surface-enhanced Raman spectroscopy (SERS) substrates were prepared by a combination of TiO2-coatings of aluminium plates through a direct titanium tetraisopropoxide (TTIP) coating and drop coated by synthesised gold nanoparticles (AuNPs). Differences between the wettability of the untreated substrates, the slowly dried Ti(OH)4 substrates and calcinated as well as plasma treated TiO2 substrates were analysed by water contact angle (WCA) measurements. The hydrophilic behaviour of the developed substrates helped to improve the distribution of the AuNPs, which reflects in overall higher lateral SERS enhancement. Surface enhancement of the substrates was tested with target molecule rhodamine 6G (R6G) and a fibre-coupled 638 nm Raman spectrometer. Additionally, the morphology of the substrates was characterised using scanning electron microscopy (SEM) and Raman microscopy. The studies showed a reduced influence of the coffee ring effect on the particle distribution, resulting in a more broadly distributed edge region, which increased the spatial reproducibility of the measured SERS signal in the surface-enhanced Raman mapping measurements on mm scale.
Surface-enhanced Raman spectroscopy (SERS) with subsequent chemometric evaluation was performed for the rapid and non-destructive differentiation of seven important meat-associated microorganisms, namely Brochothrix thermosphacta DSM 20171, Pseudomonas fluorescens DSM 4358, Salmonella enterica subsp. enterica sv. Enteritidis DSM 14221, Listeria monocytogenes DSM 19094, Micrococcus luteus DSM 20030, Escherichia coli HB101 and Bacillus thuringiensis sv. israelensis DSM 5724. A simple method for collecting spectra from commercial paper-based SERS substrates without any laborious pre-treatments was used. In order to prepare the spectroscopic data for classification at genera level with a subsequent chemometric evaluation consisting of principal component analysis and discriminant analysis, a pre-processing method with spike correction and sum normalisation was performed. Because of the spike correction rather than exclusion, and therefore the use of a balanced data set, the multivariate analysis of the data is significantly resilient and meaningful. The analysis showed that the differentiation of meat-associated microorganisms and thereby the detection of important meat-related pathogenic bacteria was successful on genera level and a cross-validation as well as a classification of ungrouped data showed promising results, with 99.5 % and 97.5 %, respectively.
In the context of the Franco-German research project Re(h)strain, this work focuses on a global system analysis integrating both safety and security analysis of international and/or urban railway stations. The Re(h)strain project focuses on terrorist attacks on high speed train systems and investigates prevention and mitigation measures to reduce the overall vulnerability and strengthen the system resilience. One main criterion regarding public transport issues is the number of passengers. For example, the railway station of Paris “Gare du Nord” deals with a bigger number of passengers than the biggest airport in the world (SNCF open Data 2014), the Atlanta airport, but in terms of passengers, it is only around the 23rd rank railway station in the world. Due to the enormous mass of people, this leads to the system approach of breaking out the station into several classes of zones, e.g. entrance, main hall, quays, trains, etc. All classes are analysed considering state-of-the-art parameters, like targets attractiveness, feasibility of attack, possible damage, possible mitigation and defences. Then, safety incidence of security defence is discussed in order to refine security requirement with regard to the considered zone. Finally, global requirements of security defence correlated to the corresponding class of zones are proposed.
A Fourier scatterometry setup is evaluated to recover the key parameters of optical phase gratings. Based on these parameters, systematic errors in the printing process of two-photon polymerization (TPP) gray-scale lithography three-dimensional printers can be compensated, namely tilt and curvature deviations. The proposed setup is significantly cheaper than a confocal microscope, which is usually used to determine calibration parameters for compensation of the TPP printing process. The grating parameters recovered this way are compared to those obtained with a confocal microscope. A clear correlation between confocal and scatterometric measurements is first shown for structures containing either tilt or curvature. The correlation is also shown for structures containing a mixture of tilt and curvature errors (squared Pearson coefficient r2 = 0.92). This compensation method is demonstrated on a TPP printer: a diffractive optical element printed with correction parameters obtained from Fourier scatterometry shows a significant reduction in noise as compared to the uncompensated system. This verifies the successful reduction of tilt and curvature errors. Further improvements of the method are proposed, which may enable the measurements to become more precise than confocal measurements in the future, since scatterometry is not affected by the diffraction limit.
The following work presents algorithms for semi-automatic validation, feature extraction and ranking of time series measurements acquired from MOX gas sensors. Semi-automatic measurement validation is accomplished by extending established curve similarity algorithms with a slope-based signature calculation. Furthermore, a feature-based ranking metric is introduced. It allows for individual prioritization of each feature and can be used to find the best performing sensors regarding multiple research questions. Finally, the functionality of the algorithms, as well as the developed software suite, are demonstrated with an exemplary scenario, illustrating how to find the most power-efficient MOX gas sensor in a data set collected during an extensive screening consisting of 16,320 measurements, all taken with different sensors at various temperatures and analytes.
The simultaneous operation of multiple different semiconducting metal oxide (MOX) gas sensors is demanding for the readout circuitry. The challenge results from the strongly varying signal intensities of the various sensor types to the target gas. While some sensors change their resistance only slightly, other types can react with a resistive change over a range of several decades. Therefore, a suitable readout circuit has to be able to capture all these resistive variations, requiring it to have a very large dynamic range. This work presents a compact embedded system that provides a full, high range input interface (readout and heater management) for MOX sensor operation. The system is modular and consists of a central mainboard that holds up to eight sensor-modules, each capable of supporting up to two MOX sensors, therefore supporting a total maximum of 16 different sensors. Its wide input range is archived using the resistance-to-time measurement method. The system is solely built with commercial off-the-shelf components and tested over a range spanning from 100Ω to 5 GΩ (9.7 decades) with an average measurement error of 0.27% and a maximum error of 2.11%. The heater management uses a well-tested power-circuit and supports multiple modes of operation, hence enabling the system to be used in highly automated measurement applications. The experimental part of this work presents the results of an exemplary screening of 16 sensors, which was performed to evaluate the system’s performance.
The choice of suitable semiconducting metal oxide (MOX) gas sensors for the detection of a specific gas or gas mixture is time-consuming since the sensor’s sensitivity needs to be characterized at multiple temperatures to find its optimal operating conditions. To obtain reliable measurement results, it is very important that the power for the sensor’s integrated heater is stable, regulated and error-free (or error-tolerant). Especially the error-free requirement can be only be achieved if the power supply implements failure-avoiding and failure-detection methods. The biggest challenge is deriving multiple different voltages from a common supply in an efficient way while keeping the system as small and lightweight as possible. This work presents a reliable, compact, embedded system that addresses the power supply requirements for fully automated simultaneous sensor characterization for up to 16 sensors at multiple temperatures. The system implements efficient (avg. 83.3% efficiency) voltage conversion with low ripple output (<32 mV) and supports static or temperature-cycled heating modes. Voltage and current of each channel are constantly monitored and regulated to guarantee reliable operation. To evaluate the proposed design, 16 sensors were screened. The results are shown in the experimental part of this work.
In the presented project, new approaches for the prevention of hand movements leading to hazards and for non-contact detection of fingers are intended to permit comprehensive and economical protection on circular saws. The basic principles may also be applied to other machines with manual loading and/or unloading. Two new detection principles are explained. The first is the distinction between skin and wood or other material by spectral analysis in the near infrared region. Using LED and photodiodes it is possible to detect fingers and hands reliable. With a kind of light curtain the intrusion into the dangerous zone near the blade can be prevented. The second principle is video image processing to detect persons, arms and fingers. In the first stage of development the detection of upper limb extremities within a defined hazard area by means of a computer based video image analysis is investigated.
The device (10) has a handrail (18) provided with an optical contactless monitoring device formed as an active sensor system, where the monitoring device is arranged in a region of a guide (14) of the handrail at a front base (16) of an escalator (12) or a moving pavement. The monitoring device has two transmission paths (28, 30) with wavelength bands that are different from each other, where one of the paths includes the handrail. Ratio or difference between signals of the paths is used for recognizing foreign bodies e.g. hands of adults and children.
The proper use of protective hoods on panel saws should reliably prevent severe injuries from (hand) contact with the blade or material kickbacks. It also should minimize long-term lung damages from fine-particle pollution. To achieve both purposes the hood must be adjusted properly by the operator for each workpiece to fit its height. After a work process is finished, the hood must be lowered down completely to the bench. Unfortunately, in practice the protective hood is fixed at a high position for most of the work time and herein loses its safety features. A system for an automatic height adjustment of the hood would increase comfort and safety. If the system can distinguish between workpieces and skin reliably, it furthermore will reduce occupational hazards for panel saw users. A functional demonstrator of such a system has been designed and implemented to show the feasibility of this approach. A specific optical sensor system is used to observe a point on the extended cut axis in front of the blade. The sensor determines the surface material reliably and measures the distance to the workpiece surface simultaneously. If the distance changes because of a workpiece fed to the machine, the control unit will set the motor-adjusted hood to the correct height. If the sensor detects skin, the hood will not be moved. In addition a camera observes the area under the hood. If there are no workpieces or offcuts left under the hood, it will be lowered back to the default position.
Modern PCR-based analytical techniques have reached sensitivity levels that allow for obtaining complete forensic DNA profiles from even tiny traces containing genomic DNA amounts as small as 125 pg. Yet these techniques have reached their limits when it comes to the analysis of traces such as fingerprints or single cells. One suggestion to overcome these limits has been the usage of whole genome amplification (WGA) methods. These methods aim at increasing the copy number of genomic DNA and by this means generate more template DNA for subsequent analyses. Their application in forensic contexts has so far remained mostly an academic exercise, and results have not shown significant improvements and even have raised additional analytical problems. Until very recently, based on these disappointments, the forensic application of WGA seems to have largely been abandoned. In the meantime, however, novel improved methods are pointing towards a perspective for WGA in specific forensic applications. This review article tries to summarize current knowledge about WGA in forensics and suggests the forensic analysis of single-donor bioparticles and of single cells as promising applications.