Refine
Departments, institutes and facilities
- Fachbereich Ingenieurwissenschaften und Kommunikation (87)
- Institut für Technik, Ressourcenschonung und Energieeffizienz (TREE) (80)
- Fachbereich Informatik (22)
- Zentrum für Innovation und Entwicklung in der Lehre (ZIEL) (6)
- Institute of Visual Computing (IVC) (4)
- Institut für funktionale Gen-Analytik (IFGA) (3)
- Fachbereich Angewandte Naturwissenschaften (2)
- Fachbereich Wirtschaftswissenschaften (2)
- Fachbereich Sozialpolitik und Soziale Sicherung (1)
- Internationales Zentrum für Nachhaltige Entwicklung (IZNE) (1)
Document Type
- Article (72)
- Conference Object (29)
- Preprint (8)
- Part of a Book (6)
- Report (4)
- Contribution to a Periodical (1)
- Doctoral Thesis (1)
- Other (1)
Year of publication
Keywords
Herein we report an update to ACPYPE, a Python3 tool that now properly converts AMBER to GROMACS topologies for force fields that utilize nondefault and nonuniform 1–4 electrostatic and nonbonded scaling factors or negative dihedral force constants. Prior to this work, ACPYPE only converted AMBER topologies that used uniform, default 1–4 scaling factors and positive dihedral force constants. We demonstrate that the updated ACPYPE accurately transfers the GLYCAM06 force field from AMBER to GROMACS topology files, which employs non-uniform 1–4 scaling factors as well as negative dihedral force constants. Validation was performed using β-d-GlcNAc through gas-phase analysis of dihedral energy curves and probability density functions. The updated ACPYPE retains all of its original functionality, but now allows the simulation of complex glycomolecular systems in GROMACS using AMBER-originated force fields. ACPYPE is available for download at https://github.com/alanwilter/acpype.
Wo Laborexperimente zu aufwendig, zu teuer, zu langsam oder zu gefährlich oder Stoffeigenschaften gar nicht erst experimentell zugänglich sind, können Computersimulationen von Atomen und Molekülen diese ersetzen oder ergänzen. Sie ermöglichen dadurch Reduktion von Kosten, Entwicklungszeit und Materialeinsatz. Die für diese Simulationen benötigten Molekülmodelle beinhalten zahlreiche Parameter, die der Simulant einstellen oder auswählen muss. Eine passende Parametrierung ist nur bei entsprechenden Kenntnissen über die Auswirkungen der Parameter auf die zu berechnenden Größen und Eigenschaften möglich. Eine Gruppe von Standardparametern in molekularen Simulationen sind die Partialladungen der einzelnen Atome innerhalb eines Moleküls. Die räumliche Ladungsverteilung innerhalb des Moleküls wird durch Punktladungen auf den Atomzentren angenähert. Für diese Annäherung existieren diverse Ansätze für verschiedene Molekülklassen und Anwendungen. In diesem Teilprojekt des Promotionsvorhabens wurde systematisch der Einfluss der Wahl des Partialladungssatzes auf potentielle Energien und ausgewählte makroskopische Eigenschaften aus Molekulardynamik-Simulationen evaluiert. Es konnte gezeigt werden, dass insbesondere bei stark polaren Molekülen die Auswahl des geeigneten Partialladungssatzes entscheidenden Einfluss auf die Simulationsergebnisse hat und daher nicht naiv, sondern nur ganz gezielt getroffen werden darf.
Integrating physical simulation data into data ecosystems challenges the compatibility and interoperability of data management tools. Semantic web technologies and relational databases mostly use other data types, such as measurement or manufacturing design data. Standardizing simulation data storage and harmonizing the data structures with other domains is still a challenge, as current standards such as the ISO standard STEP (ISO 10303 ”Standard for the Exchange of Product model data”) fail to bridge the gap between design and simulation data. This challenge requires new methods, such as ontologies, to rethink simulation results integration. This research describes a new software architecture and application methodology based on the industrial standard ”Virtual Material Modelling in Manufacturing” (VMAP). The architecture integrates large quantities of structured simulation data and their analyses into a semantic data structure. It is capable of providing data permeability from the global digital twin level to the detailed numerical values of data entries and even new key indicators in a three-step approach: It represents a file as an instance in a knowledge graph, queries the file’s metadata, and finds a semantically represented process that enables new metadata to be created and instantiated.
Off-lattice Boltzmann methods increase the flexibility and applicability of lattice Boltzmann methods by decoupling the discretizations of time, space, and particle velocities. However, the velocity sets that are mostly used in off-lattice Boltzmann simulations were originally tailored to on-lattice Boltzmann methods. In this contribution, we show how the accuracy and efficiency of weakly and fully compressible semi-Lagrangian off-lattice Boltzmann simulations is increased by velocity sets derived from cubature rules, i.e. multivariate quadratures, which have not been produced by the Gauss-product rule. In particular, simulations of 2D shock-vortex interactions indicate that the cubature-derived degree-nine D2Q19 velocity set is capable to replace the Gauss-product rule-derived D2Q25. Likewise, the degree-five velocity sets D3Q13 and D3Q21, as well as a degree-seven D3V27 velocity set were successfully tested for 3D Taylor-Green vortex flows to challenge and surpass the quality of the customary D3Q27 velocity set. In compressible 3D Taylor-Green vortex flows with Mach numbers Ma={0.5;1.0;1.5;2.0} on-lattice simulations with velocity sets D3Q103 and D3V107 showed only limited stability, while the off-lattice degree-nine D3Q45 velocity set accurately reproduced the kinetic energy provided by literature.
In this contribution, we perform computer simulations to expedite the development of hydrogen storages based on metal hydride. These simulations enable in-depth analysis of the processes within the systems which otherwise could not be achieved. That is, because the determination of crucial process properties require measurement instruments in the setup which are currently not available. Therefore, we investigate the reliability of reaction values that are determined by a design of experiments.
Specifically, we first explain our model setup in detail. We define the mathematical terms to obtain insights into the thermal processes and reaction kinetics. We then compare the simulated results to measurements of a 5-gram sample consisting of iron-titanium-manganese (FeTiMn) to obtain the values with the highest agreement with the experimental data. In addition, we improve the model by replacing the commonly used Van’t-Hoff equation by a mathematical expression of the pressure-composition-isotherms (PCI) to calculate the equilibrium pressure.
Finally, the parameters’ accuracy is checked in yet another with an existing metal hydride system. The simulated results demonstrate high concordance with experimental data, which advocate the usage of approximated kinetic reaction properties by a design of experiments for further design studies. Furthermore, we are able to determine process parameters like the entropy and enthalpy.
In an effort to assist researchers in choosing basis sets for quantum mechanical modeling of molecules (i.e. balancing calculation cost versus desired accuracy), we present a systematic study on the accuracy of computed conformational relative energies and their geometries in comparison to MP2/CBS and MP2/AV5Z data, respectively. In order to do so, we introduce a new nomenclature to unambiguously indicate how a CBS extrapolation was computed. Nineteen minima and transition states of buta-1,3-diene, propan-2-ol and the water dimer were optimized using forty-five different basis sets. Specifically, this includes one Pople (i.e. 6-31G(d)), eight Dunning (i.e. VXZ and AVXZ, X=2-5), twenty-five Jensen (i.e. pc-n, pcseg-n, aug-pcseg-n, pcSseg-n and aug-pcSseg-n, n=0-4) and nine Karlsruhe (e.g. def2-SV(P), def2-QZVPPD) basis sets. The molecules were chosen to represent both common and electronically diverse molecular systems. In comparison to MP2/CBS relative energies computed using the largest Jensen basis sets (i.e. n=2,3,4), the use of smaller sizes (n=0,1,2 and n=1,2,3) provides results that are within 0.11--0.24 and 0.09-0.16 kcal/mol. To practically guide researchers in their basis set choice, an equation is introduced that ranks basis sets based on a user-defined balance between their accuracy and calculation cost. Furthermore, we explain why the aug-pcseg-2, def2-TZVPPD and def2-TZVP basis sets are very suitable choices to balance speed and accuracy.