Today, more than 70 million tons of lignin are produced by the pulp and paper industry every year. However, the utilization of lignin as a source for chemical synthesis is still limited due to the complex and heterogeneous lignin structure. The purpose of this study was a selective photodegradation of industrially available kraft lignin in order to obtain appropriate fragments and building block chemicals for further utilization, e.g. polymerization. Thus, kraft lignin obtained from soft wood black liquor by acidification was dissolved in sodium hydroxide and irradiated at a wavelength of 254 nm with and without the presence of titanium dioxide in various concentrations. Analyses of the irradiated products via SEC showed decreasing molar masses and decreasing polydispersity indices over time. At the end of the irradiation period the lignin was depolymerised to form fragments as small as the lignin monomers. TOC analyses showed minimal mineralisation due to the depolymerisation process.
Suitability of Current Sensors for the Measurement of Switching Currents in Power Semiconductors
(2021)
This paper investigates the impact of current sensors on the measurement of transient currents in fast-switching power semiconductors in a double pulse test (DPT environment. We review previous research that assesses the influence of current sensors on a DPT circuit through mathematical modeling. The developed selection aids can be used to identify suitable current sensors for transient current measurements of fast-switching power semiconductors and to estimate the error introduced by their insertion into the DPT circuit. Afterwards, this analysis is extended by including further elements from real DPT applications to increase the consistency of the error estimation with practical situations and setups. Both methods are compared and their individual advantages and drawbacks are discussed. Finally, a recommendation on when to use which method is derived.
This paper investigates the effect of voltage sensors on the measurement of transient voltages for power semiconductors in a Double Pulse Test (DPT) environment.We adapt previously published models that were developed for current sensors and apply them to voltage sensors to evaluate their suitability for DPT applications. Similarities and differences between transient current and voltage sensors are investigated and the resulting methodology is applied to commercially available and experimental voltage sensors. Finally, a selection aid for given measurement tasks is derived that focuses on the measurement of fast-switching power semiconductors.