006 Spezielle Computerverfahren
Refine
H-BRS Bibliography
- no (27) (remove)
Departments, institutes and facilities
Document Type
- Article (10)
- Conference Object (10)
- Part of a Book (3)
- Book (monograph, edited volume) (1)
- Research Data (1)
- Doctoral Thesis (1)
- Patent (1)
Year of publication
Has Fulltext
- no (27)
Keywords
This paper describes a dynamic, model-based approach for estimating intensities of 22 out of 44 different basic facial muscle movements. These movements are defined as Action Units (AU) in the Facial Action Coding System (FACS) [1]. The maximum facial shape deformations that can be caused by the 22 AUs are represented as vectors in an anatomically based, deformable, point-based face model. The amount of deformation along these vectors represent the AU intensities, and its valid range is [0, 1]. An Extended Kalman Filter (EKF) with state constraints is used to estimate the AU intensities. The focus of this paper is on the modeling of constraints in order to impose the anatomically valid AU intensity range of [0, 1]. Two process models are considered, namely constant velocity and driven mass-spring-damper. The results show the temporal smoothing and disambiguation effect of the constrained EKF approach, when compared to the frame-by-frame model fitting approach ‘Regularized Landmark Mean-Shift (RLMS)’ [2]. This effect led to more than 35% increase in performance on a database of posed facial expressions.
A method for minimum range extension with improved accuracy in triangulation laser range finder
(2011)
Introduction. The experience of pain is regularly accompanied by facial expressions. The gold standard for analyzing these facial expressions is the Facial Action Coding System (FACS), which provides so-called action units (AUs) as parametrical indicators of facial muscular activity. Particular combinations of AUs have appeared to be pain-indicative. The manual coding of AUs is, however, too time- and labor-intensive in clinical practice. New developments in automatic facial expression analysis have promised to enable automatic detection of AUs, which might be used for pain detection. Objective. Our aim is to compare manual with automatic AU coding of facial expressions of pain. Methods. FaceReader7 was used for automatic AU detection. We compared the performance of FaceReader7 using videos of 40 participants (20 younger with a mean age of 25.7 years and 20 older with a mean age of 52.1 years) undergoing experimentally induced heat pain to manually coded AUs as gold standard labeling. Percentages of correctly and falsely classified AUs were calculated, and we computed as indicators of congruency, "sensitivity/recall," "precision," and "overall agreement (F1)." Results. The automatic coding of AUs only showed poor to moderate outcomes regarding sensitivity/recall, precision, and F1. The congruency was better for younger compared to older faces and was better for pain-indicative AUs compared to other AUs. Conclusion. At the moment, automatic analyses of genuine facial expressions of pain may qualify at best as semiautomatic systems, which require further validation by human observers before they can be used to validly assess facial expressions of pain.